Troubleshooting - Graco 308972R Instructions-Parts List Manual

Gh series roof rigs gas-hydraulic airless sprayers
Table of Contents

Advertisement

WARNING
SKIN INJECTION HAZARD
To reduce the risk of serious injury,
whenever you are instructed to relieve
pressure, follow the Pressure Relief
Procedure on page 10.
Check everything in the troubleshooting chart before disassembling the sprayer.
PROBLEM
Gas engine doesn't work properly.
Gas engine will not start.
Gas engine operates, but
displacement pump doesn't
operate.
Displacement pump operates, but
output is low on upstroke.
Displacement pump operates but
output is low on downstroke and/
or on both strokes.
Paint leaks into wetcup.
Excessive leakage around
hydraulic motor piston rod wiper.
Fluid delivery is low.
The sprayer overheats.
Spitting from gun.
*Check hydraulic fluid level often. Do not allow it to become too low. Use only Graco approved hydraulic fluid. See pages 6 and 37.

Troubleshooting

CAUSE
Hydraulic motor stalled.
Pressure setting too low.
Displacement pump outlet filter (if
used) is dirty or clogged.
Tip or tip filter (if used) is clogged.
Hydraulic fluid too low.
Hydraulic pump worn or damaged.
Hydraulic motor worn or damaged.
Displacement pump rod seized by
dried paint.
Piston ball check not seating properly.
Piston packings worn or damaged.
Piston packings worn or damaged.
Intake valve ball check not seating
properly.
Loose wet--cup.
Throat packings worn or damaged.
Piston rod seal worn or damaged.
Pressure setting too low.
Displacement pump outlet filter (if
used) is dirty or clogged.
Hydraulic pump is worn or damaged.
Hydraulic motor is worn or damaged.
Large pressure drop in fluid hose.
Cooler or blower is worn or damaged.
Air in fluid pump or hose.
Fluid supply is low or empty.
SOLUTION
Consult engine manual, supplied.
Check battery.
Turn the ignition key to OFF. Firmly press
straight down on motor reset button. Restart
sprayer, see page 10. If it doesn't start, see
manual 307158.
Increase pressure. See page 11.
Clean the filter.
Remove tip and/or filter and clean.
Shut off sprayer and add fluid immediately*. See
page 5.
Return sprayer for repair.
Return sprayer for repair.
Service pump. See pump manual.
Service piston ball check. See pump manual.
Replace packings. See pump manual.
Replace packings. See pump manual.
Service intake valve ball check. See pump
manual.
Tighten just enough to stop leakage.
Replace packings. See pump manual.
Replace these parts. See manual 307158.
Increase pressure. See page 11.
Clean filter.
Return sprayer for repair.
Return sprayer for repair.
Use larger diameter hose.
Replace. See page 15.
Check for loose connections on siphon
assembly, tighten, then reprime pump.
Refill supply container.