Electrical Connection - Hoshizaki KM-900MAF Instruction Manual

Modular crescent cuber
Hide thumbs Also See for KM-900MAF:
Table of Contents

Advertisement

5. ELECTRICAL CONNECTION

1. Electrical connection must be made in accordance with the instructions on a
"WARNING" tag, provided with the pig tail leads in the Junction Box.
2. This icemaker requires a ground that meets the national and local electrical
code requirements. To prevent possible electrical shock to individuals or
extensive damage to the equipment, install a proper ground wire to the
icemaker.
• On single phase models only, the white lead must be connected to the neutral conductor of the
power source. Miswiring results in severe damage to the icemaker. See Fig. 3.
• On three phase models, the Voltage Tap Switch in the unit should be positioned to match
incoming voltage at start-up. See Fig. 4.
• This icemaker must have a separate power supply or receptacle of proper capacity. See the
Nameplate.
• The opening for the power supply connection is 7/8" DIA to fit a 1/2" trade size conduit.
• Usually an electrical permit and services of a licensed electrician are required.
A1JA10A9810
Fig. 3
WARNING
11
Fig. 4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Km-900mwfKm-900mrfKm-900mrf3

Table of Contents