Console Login Configuration - Alcatel OMNISTACK 8008 User Manual

Switch
Hide thumbs Also See for OMNISTACK 8008:
Table of Contents

Advertisement

Console Login Configuration

Use the Management Setup: Console Login Configuration to restrict management
access based on specified user names and passwords, or to set the invalid
password threshold and timeout. There are only two user types defined, ADMIN
(Administrator) and GUEST, but you can set up to five different user names and
passwords. Only Administrators have write access for parameters governing the
switch. You should therefore assign a user name and password to the default
Administrator as soon as possible, and store it in a safe place. (If for some reason
your password is lost, or you cannot gain access to the system configuration
program, contact Alcatel Technical Support for assistance.) The parameters shown
on this screen are indicated in the following figure and table.
----------------------------------------------------------
Use <TAB> or arrow keys to move, other keys to make changes.
Parameter
Default
Password
3
Threshold
Lock-out
0
Time
Admin*
name: admin
password: switch
Guest*
name: user
password: switch
* Passwords can consist of up to 11 alphanumeric characters and are not case sensitive.
Alcatel OmniStack 8008
< Console Login Configuration >
Password Threshold
Lock-out Time (in minutes) : 0
User Type
User Name
1.
ADMIN
2.
GUEST
3.
4.
5
<APPLY>
Description
Sets the password intrusion threshold which limits the number
of failed logon attempts. Range : 0~65535
Time (in minutes) the management console will be disabled,
Range : 0~65535
Administrator has access privilege of Read/Write for all
screens.
Guest has access privilege of Read Only for all screens.
: 3
Password
admin
******
guest
<OK>
Management Setup Menu
Confirm password
******
<CANCEL>
2-17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Omnistack 8008

Table of Contents