General safety instructions

Caution!
Overfilling the holding tank can create serious damage to the sanitation system, such as
rupturing the holding tank and releasing tank contents into the bilge . To prevent this pos-
sibility, Dometic recommends using the "full" tank shut-down relay in the toilet's electronic
control module . The "full" signal from the holding tank can be generated by an optional
Dometic DTM01C tank monitor or DTM04 four-level tank monitor system .
3

Intended use

The SeaLand MasterFlush toilet provides an electric-flush toilet that macerates waste and pumps
it to a holding tank or other effluent storage/disposal system . Operated by a wall-mounted flush
switch, the toilet allows the user to add water to the bowl (before using or flushing) and to flush the
toilet by pushing a button . The Dometic flush switch panel includes lights to indicate when electric
power to the toilet is activated, and when the holding tank (if applicable) is full .
3.1
Benefits
Convenient electronic flush. Add water or flush with the touch of a button .
Choice of two water consumption settings. "Normal" flush uses 0 .85 gal . (3 .2 liters) per flush and adds
water to bowl after flush; "Dry Bowl" setting uses only 0 .45 gal . (1 . 7 liters) per flush and does not add
water to the bowl .
Versatile installation. Powerful macerator pump allows toilet to be located up to 98 ft . (30 m) away and
9 .8 ft . (3 m) below holding tank or other discharge line destination .
"Power on" and "full tank" indicator lights. Dometic or other flush switch panel indicates when
electrical power to toilet is activated, and when holding tank is full (when connected to holding tank level
indication system) .
Automatic "full tank" shut-down. When connected to a holding tank level indication system, the
MasterFlush toilet control module will shut off electrical power to the toilet when the holding tank is full .
This safety features prevents overfilling the holding tank, which may cause damage to the boat .
4

Components

1
(fig .
, page 2)
Ref.
Description
A
Macerator toilet
B
Dometic flush switch/status panel
C
Control module
D
4-wire cable to toilet
E
Cable from Dometic flush switch
F
6-wire cable to Vimar/Gewiss
flush switch/status panel (optional)
4
SeaLand MasterFlush Toilet
Ref.
Description
G
Incoming electrical power wires
H
Power wires to raw water pump (opt .)
I
Wire from "full tank" signal
J
Floor mounting hardware kit
K
Floor mounting template
Refer to complete parts list (packed separately)
for additional information .