Structure Options

To make adjustments to StructureScan display
settings, highlight Structure Options on the
StructureScan menu and press EntEr.

Structure Surface Clarity

Adjusts sensitivity near the surface of the water to reduce or eliminate onscreen
clutter caused by wave action, boat wakes, temperature inversion, etc.
Structure Surface Clarity turned off.
To adjust Surface Clarity:
1.
Select
and press EntEr.
2.
Use the keypad to select the desired setting and press

Structure Noise Rejection

Reduces onscreen clutter caused by bilge pumps, engine vibration, air bubbles or
other transducers on your boat.
To turn Structure Noise Rejection On/Off,
highlight Structure Noise Rejection on the
Structure Options menu and press EntEr.

Flip Left/Right

Controls the orientation of the sidescan/downscan onscreen display.
If the transducer is installed with the cabled end pointing away from the back of
your boat or pointing away from the front of your trolling motor, you must turn on
Flip Left/Right.
Structure Surface Clarity from the Structure Options menu
Structure Options menu
Structure Surface Clarity on High.