Commissioning

When the hob has been fully installed it will be necessary to check the minimum
flame setting. To do this, follow the procedure below.
! ! ! ! !
1) Turn the gas tap to the MAX position and ignite.
2) Set the gas tap to the MIN flame position then turn the control knob
from MIN to MAX several times. If the flame is unstable or is extinguished
follow the procedure below.
Procedure:
! ! ! ! !
1) Re-ignite the burner and set to MIN.
2) Remove the control knob.
3) To adjust, use a thin bladed
screwdriver
adjustment screw (see diagram)
until the flame is steady and does
not extinguish, when the knob is
turned from MIN to MAX. Repeat
this procedure for all burners.

Pressure Testing

The pressure testing must becarried out on the burners.
! ! ! ! !
Proceed as follows:
1) Remove the pan supports and the burner caps and crowns.
2) Fit manometer tube over the injector.
3) Turn on the burner gas supply and ignite another burner supply.
The pressure reading should be nominally 20 mbar and must be between
17 mbar and 25 mbar.
4) Turn off the burner supplies.