Danby Premiere DPAC 9009 Owner's Use And Care Manual

Danby Premiere DPAC 9009 Owner's Use And Care Manual

Portable
Hide thumbs Also See for Premiere DPAC 9009:
Table of Contents

Advertisement

Available languages

Available languages

Owner's Use and Care Guide
Guide de soin d'utiliser-et
Guía a utilizar y a cuidar
Model • Modèle
DPAC 9009
CAUTION: Read and follow all safety rules and operating instructions before first use
of this product.
MISE EN GARDE : Veuillez lire attentivement les consignes de sécurité et les directives
d'utilisation avant l'utilisation initiale de ce produit.
PORTABLE AIR CONDITIONER
Table of contents . . . . . . . . . . . . . . . . . . . . . .
1
CLIMATISEUR PORTATIF
Table des matières . . . . . . . . . . . . . . . . . . . . 13
KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE: If the Dehumidifier changes
ownership, be sure this manual accompanies the unit.
CONSERVER CES INSTRUCTIONS POUR CONSULTATION ULTÉRIEURE: En cas de revente
du déshumidificateur, ce manuel doit être inclus avec l'appareil.
Danby Products Ltd, PO Box 1778, Guelph, Ontario Canada N1H 6Z9
Danby Products Inc, PO Box 669, Findlay, Ohio USA 45839-0669
Version 1.10.08 JF

Advertisement

Table of Contents
loading

Summary of Contents for Danby Premiere DPAC 9009

  • Page 1 CONSERVER CES INSTRUCTIONS POUR CONSULTATION ULTÉRIEURE: En cas de revente du déshumidificateur, ce manuel doit être inclus avec l’appareil. Danby Products Ltd, PO Box 1778, Guelph, Ontario Canada N1H 6Z9 Danby Products Inc, PO Box 669, Findlay, Ohio USA 45839-0669...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS UNIT SPECIFICATIONS ......2 PART IDENTIFICATION ......3 IMPORTANT SAFETY INFORMATION Electrical Specifications .
  • Page 3: Unit Specifications

    WELCOME Thank you for choosing a Danby appliance to provide you and your family with all of the “Home Comfort” requirements of your home, cottage, or office. This Owner’s Use and Care Guide will provide you with valuable information necessary for the proper care and maintenance of your new appliance. If properly maintained, your Danby appliance will give you many years of trouble free operation.
  • Page 4: Part Identification

    PART IDENTIFICATION Air Exhaust Air Filter Display Air inlet Handles Air outlet Air inlet Cover Front Panel Electricity Water drain Wheels cable IMPORTANT SAFETY INFORMATION READ ALL SAFETY INFORMATION BEFORE USING ELECTRICAL SPECIFICATIONS TABLE 1 1) Check available power supply and resolve any wiring problems BEFORE Suggested Individual Branch Circuit installation and operation of this unit.
  • Page 5: Energy Saving Tips

    ENERGY- Your Danby appliance is designed to be highly efficient in energy savings. Follow these recommendations for greater efficiency. SAVING TIPS 4) Start your air conditioner before the...
  • Page 6: Installation

    INSTALLATION ELECTRIC SHOCK HAZARD: To avoid the possibility of personal INSTALLATION injury, disconnect power to the unit before installing or servicing. Flexible Exhaust Hose (13cm) & Exhaust Fig. 1 INSTALLATION ACCESSORIES nozzle connector (2 pcs)... from 17 ” (45cm) Flexible Exhaust Hose up to 53 ”...
  • Page 7: Features Of The Control Panel

    OPERATION- Features of the Control Panel Receiving Sensor Warning Light NOTE: By pressing both KEY PAD FUNCTIONS buttons at the same time for more POWER SWITCH:Turns unit ON/OFF than 3 seconds, the display will toggle between Celsius and MODE: Allows you to scroll through and Fahrenheit.
  • Page 8: Air Conditioning

    OPERATING INSTRUCTIONS IMPORTANT: The exhaust hose must be properly vented (outdoors) during air conditioning mode. CONDITIONING 1) Press the POWER SWITCH key (Fig. A) to switch Fig. A on the unit, and the previous set temperature will be shown in the temperature display area of the control panel.
  • Page 9: Dehumidifier

    OPERATING INSTRUCTIONS (cont’d) DEHUMIDIFIER Fig. G Note: During dehumidifier mode, the exhaust hose does not have to be vented outdoors. 1) Press the ON/OFF key pad to switch the unit on (Fig. G) 2) Press the MODE key (Fig. H) until the DRY indicator illuminates on the control panel (Fig.I).Each Fig.
  • Page 10: Auto Timer

    OPERATING INSTRUCTIONS (cont’d) The AUTO-TIMER feature offers a unique selection of multiple AUTO-TIMER choice, fully automatic on and/or off (start/stop) programs between 1-24 hours under any one mode of your Home Comfort unit. The programs are as follows: a) Auto-Off: Pre-select a time that will turn off the unit automatically (between 1-12hrs). b) Auto-On: Pre-select a time that will turn on the unit automatically (between 1-12hrs).
  • Page 11: Care And Maintenance

    CARE AND MAINTENANCE CLEANING THE UNIT CAUTION: Before cleaning or servicing this unit, disconnect from any electrical supply outlet. 1) DO NOT use gasoline, benzene, thinner, or any other chemicals to clean this unit, as these substances may cause damage to the finish and deformation of plastic parts. 2) Never attempt to clean the unit by pouring water directly over any of the surface areas, as this will cause deterioration of electrical components and wiring insulation.
  • Page 12: Troubleshooting

    TROUBLESHOOTING PROBLEM POSSIBLE CAUSE SOLUTION • Wait for power to return • Unit does not work • Power is out • Plug in properly • The plug is not plugged in properly • Remove drain water from • The full-tank indicator is ON; tank the drain tank is full •...
  • Page 13: Warranty

    This quality product is warranted to be free from manufacturer’s defects in material and workmanship, provided that the unit is used under the normal operating conditions intended by the manufacturer. This warranty is available only to the person to whom the unit was originally sold by Danby or by an authorized distributor of Danby, and is non-transferable. TERMS OF WARRANTY Plastic parts, are warranted for thirty (30) days only from purchase date, with no extensions provided.
  • Page 14 TA B L E D E S M AT I ÉRES SPÉCIFICATIONS DE L’UNITÉ ..... 14 IDENTIFICATION DE PARTIE ..... . .15 CONSIGNES DE SÉCURITÉ...
  • Page 15: Spécifications De L'unité

    BIENVENUE Merci d’avoir choisi un appareil Danby qui vous fournira ainsi qu’à votre famille, le confort au foyer, à la maison, au chalet ou au bureau. Ce manuel d’utilisation vous offre des renseignements pratiques pour le soin et l’entretien de votre nouvel appareil. Un appareil Danby bien entretenu vous fournira plusieurs années de service sans ennui.
  • Page 16: Identification De Partie

    IDENTIFICATION DE PARTIE Échappement d’air Filtre à air Affichage Entrée d’air Poignées Sortie d’air Entrée Panneau d’air Frontal Couvercle Câble Drain à eau Roues électrique CONSIGNES DE SÉCURITÉ IMPORTANT LISEZ TOUTE L'INFORMATION DE SÉCURITÉ AVANT UTILISATION SPÉCIFICATIONS ÉLECTRIQUES TABLEAU 1 1) Vérifier l’alimentation de courant disponible et Circuit de distribution individuel suggéré...
  • Page 17: Suggestions Pour Économiseur D'énergie

    ‘TEST’ aussi indiqué par une lumière sur la tête de la est enfoncé. fiche). Votre appareil ménager Danby est conçu pour l’efficacité en SUGGESTIONS économie de l’énergie. Pour le rendement maximal, observer les POUR L’ÉCONOMIE DE recommandations qui suivent.
  • Page 18: Installation

    INSTALLATION RISQUE DE CHOC ÉLECTRIQUE: Pour éviter la possibilité de blessures INSTALLATION corporelles, débrancher l’alimentation de courant à l’unité avant d’entreprendre l’installation ou le service. Tuyay d’echappement flexible (13cm) & bec Fig. 1 Accessoires D’Installation connecteur d’échappement (2 mcx)... de 17 Tuyau d’échappement (45cm) jusqu’à...
  • Page 19: Dispositifs Du Panneau De Commande

    FONCTIONNEMENT - Caractéristique du panneau de commande Détecteur récepteur Lampe témoin NOTE : Pressez tous les boutons FONCTIONS DE BLOC NUMÉRIQUE en même temps pendant INTERRUPTEUR D’ALIMENTATION: Permet de mettre l’appareil en Marche/Arrêt plus de 3 secondes, et l'affichage alterneront Celsius et Fahrenheit. MODE: Vous permet fair défiler et de sélectionner le mode de fonctionnement désiré...
  • Page 20: Climatisation

    FONCTIONNEMENT REMARQUE: Le tuyau flexible pour l’échappement d’air doivent être installés pour le fonctionnement en mode de CLIMATISEUR climatisation 1) Appuyer sur la touche INTERRUPTEUR (Fig. A) pour activer l’unité et le réglage précédent du Fig. A température sera montrée dans l’affichage de la température sur le panneau de commande.
  • Page 21: Déshumidificateur

    FONCTIONNEMENT (suite) DÉSHUMIDIFICATEUR Fig. G REMARQUE: L’installation du tuyau flexible pour l’echappement d’air n’est pas requise pour le fonctionnement en mode de Déshumidification. 1) Appuyer sur la touche INTERRUPTEUR pour activer l’unité (Fig. G). 2) Appuyer sur la touche MODE (Fig. H) jusqu’à l’affichage du symbole Déshumidification sur le Fig.
  • Page 22: Minuterie Automatique

    FONCTIONNEMENT (suite) La caractéristique de la MINUTERIE AUTOMATIQUE offre une sélection MINUTERIE unique de plusieurs choix, entièrement automatique et/ou programmes AUTOMATIQUE d'arrêt (démarrage/arrêt) entre 1 à 12 heures dans tous les modes de votre Unité de confort à la maison. Les programmes sont comme suit: a) Arrêt automatique : Sélectionnez une heure à...
  • Page 23: Soins Et Entretien

    SOINS ET ENTRETIEN NETTOYAGE DE L'UNITÉ MISE EN GARDE: Avant de nettoyer ou de faire le service sur cette unité, il est recommandé de débrancher le cordon d’alimentation de la prise de courant électrique. 1) NE PAS utliser d’essence, de benzène, de diluant ou tous autres produits chimiques pour nettoyer cette unité.
  • Page 24: Dépannage

    DÉPANNAGE PROBLEME CAUSE PROBABLE SOLUTION • Attendez que • L'unité ne fonctionne pas • Il n'y a pas d'alimentation l'alimentation revienne • La fiche n'est pas branchée • Branchez adéquatement adéquatement • Enlevez l'eau du drain du • L'indicateur du réservoir plein est réservoir du drain en MARCHE;...
  • Page 25: Garantie

    En vertu de la présente, Danby Products Limitée (Canada) ou Danby Products Inc. (E.- U. d’A.) ne peut être tenue responsable en cas de blessures corporelles ou des dégâts matériels, y compris à l’appareil, quelle qu’en soit les causes. Danby ne peut pas être tenue responsable des dommages indirects dus au fonction- nement défectueux de l’appareil.