External Interface; Optional Features - GE Digital Energy Datasheet

Sg series uninterruptable power supply 225-300kva ul listed with eboost digital energy
Hide thumbs Also See for Digital Energy:

Advertisement

g
Alarm contacts (voltage-free)
Communication
Input signals
Mimic Diagram
Operation LED
Alarm LED
Warning LED
Load Level / Battery Run Time
Multilanguage Graphic LCD
Push Buttons
RPA, IEMi
eBoost™ (Patented) Operating Mode
RPA Cable Saver Inductor
FCC Filter
Dual Input
Input/Output Transformers
External Maintenance Bypass
Remote Status Panel
Protection Software
SNMP Communication
g
imagination at work
Energy
Digital Energy
Technical Data Sheet - 225-300kVA UL Listed

External Interface

Standard :
Optional :
Front Panel Controls, Signals & Alarms

Optional Features

6 user defined contacts (form 'C') (1A / 24V DC)
12 user defined contacts (form 'C') (1A / 24V DC)
(23 selectable signals include aux. Inputs 1 & 2)
RS-232 / SNMP / MODBUS
Emergency Power Off (user supplied N.C. contact)
Aux. input 1
* (default = On Generator)
Aux. input 2
* (configurable)
* Status displayed on LCD panel
Represents operational status of the UPS on Home Page of LCD
Visual (LED) when load is on inverter OR load is on bypass
BLINK during service check
Visual (LED) and audible signal, activates approx. 3 minutes
(adjustable) before complete and automatic load shutdown due to the
battery is fully discharged and the load cannot be transferred on
utility or Over temperature or overload condition (>125%) and the load
cannot be transferred on utility.
Visual (LED) and audible signal active when any alarm condition is
present
BLINK when alarm is active and not acknowledged
Bar graph status indicator on Home Page of LCD
Load level in %, Battery run time in min.
Display of UPS metering functions , event history, configuration of
parameters and helps perform critical UPS Operations
Supports 14 Languages(Chinese, Czech, Dutch, English, Espanola,
Francais, German, Italiano, Polish, Portuguese, Russian, Slovensko,
Soumi, Swedish)
-Inverter On
-Inverter Off
-Total Off with protective cover
-Redundant Parallel Operation, Intelligent Energy Management
Integrated
-High Efficiency Operating Mode for Single and Multi module
applications
-Simplify Parallel Systems installation & Improve current sharing
-Brings UPS into compliance with FCC, Class A Specifications
-Integral to UPS cabinet. No additional cabinet required
-Available in external cabinets for isolation or voltage transformation
-Available in external or as a part of output switchgear cabinet
-Active mimic diagram w/ Stop Operation and Summary Alarms
-PC operated remote monitoring, control and diagnostics
-Ethernet interface for network connection
GEA-D2041 (225 300kVA TDS), Page: 4