Assembly; Double Deck Units - Garland MASTER Installation And Operation Manual

Half-size gas convection oven
Hide thumbs Also See for MASTER:
Table of Contents

Advertisement

INSTALLATION Continued

Assembly

All units are equipped with N.S.F. approved legs. These
legs must be installed to provide a minimum 6" (153mm)
clearance between the floor and the bottom of the unit in
order to meet national Sanitation Foundation requirements.
A. To install the legs, raise the front of the unit and block
it. Insert the two front legs into the conical leg retainers.
Repeat at the rear.
B. Level the unit by placing a carpenter's-type level on one
of the oven racks, and adjust each leg by turning its "foot"
to raise or lower the height of the leg. The bottom of each
"foot" is hexagonal in shape so that a wrench may be
used.

Double Deck Units

A. Install legs as above to the bottom unit.
B. Remove the combustion chamber from the top unit and
raise it into place. Align the body sides and backs of the
two units.
C. Using the angle bracket provided, fasten the bottom
front of the top unit to the main top of the bottom unit,
near the center, as shown.
Angle Bracket
Top of Bottom Deck
D. Replace the combustion chamber on the top unit,
and fasten the two units together at the rear with the
mounting plates and screws provided.
E. Install the two flue boxes and the flue riser to the rear of
the stack as shown.
F. Assemble the interconnecting gas piping as shown.
Part # 1844082 (11/03/08)
Bottom of
Top Deck
SIDE VIEW
G. Start by threading the two tailpipes. Be sure to use a pipe
thread compound that is suitable for use on gas fittings.
H. Next install the 90° street elbow on the nipple of the top
unit, and then install the male part of the union on the
street elbow.
I. Install the 3/4" x 3/4" x 1" tee nipple of the bottom unit.
J. Install the 28-1/4" connection pipe to the second 3/4"
inlet on the tee, then install the male part of the union to
the other end of the connection pipe. Be sure to slide the
union's hex-shaped fastening ring over the connecting
pipe before installing the male half.
K. Connect the top and bottom units' piping with the union
as shown.
CAUTION: Disconnect both units from electrical supply
before servicing.
Flue
Riser
Flue Boxes
Mounting
Plates
REAR VIEW
3/4" 90 Deg
Street Elbow
3/4" Close
3/4" Standard
Nipple
Female Union
28 1/4"
Connecting Pipe
3/4" Close
3/4" X 3/4" X 1"
Nipple
Reducing Tee
1" NPT
Gas Inlet
Page 7