Compartment Floor Cutouts - Generac Power Systems 004700-0 Installation And Owner's Manual

Air-cooled recreational vehicle generators
Table of Contents

Advertisement

Figure 2.7 – Typical Noise Abatement
Figure 2.8 – Compartment Floor Cutout (Drawing 0D8716-C)
HOT AIR
EXHAUST
427.7
376.5
TAIL PIPE
EXIT
29
VIEW FROM TOP
429.9
350.1
24.7
50.8
277.2
210
79
10
36.5
54.8 TYP.
229.4
307.4
376.4
All measurements are in millimeters, 25.4 mm = 1".
Section 2 – Installation
QUIETPACT 40G Recreational Vehicle Generator

2.2.5 COMPARTMENT FLOOR CUTOUTS

You must provide openings in the generator compart-
ment for the following items (Figure 1.2, page 21):
• Engine exhaust and cooling air outlets
• Generator cooling air inlet
• Four holes for passage of generator mounting
bolts. See Section 2.1.4 (Page 23).
Fuel lines and exhaust piping must not pene-
!
trate into the vehicle living area.
724.4
32.2
60
259.7
AIR
INTAKE
176.6
83.5
OIL DRAIN
695 TYP.
DANGER
59.2
11
170
63.5
Generac
®
Power Systems, Inc. 25
NO
5/16"-18 WELDNUTS
(6 PLACES)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Guardian rv 004700-0Guardian rv quietpact 40g

Table of Contents