ow to dehumidify
1) Plug the appliance into a mains socket.
2) Check that the "tank full/tank missing" light is off.
3) Select the
standby light remains on during the first 3 minutes (safety device), after which the dehu-
midification light switches on.
4) The humidistat knob is used to adjust the humidity level as desired (MIN/MED/MAX). When the
knob is on MIN, the dehumidifier will slightly reduce the humidity in the room; on MAX, on the
other hand, the appliance will considerably reduce the humidity in the room. Then turn the
humidistat to one of the positions available.
Turn the humidistat to the MAX position. When the humidity has reached the required level
(this can take several weeks), slowly turn the humidistat knob anticlockwise until the dehu-
midifying light goes out. The dehumidifier will then keep the humidity in the room at the
selected level automatically.
Dehumidification indicator light
Dehumidification
power knob
H
ow to heat
1) Plug the appliance into a mains socket.
2) It is possible to adjust the room temperature by turning the thermostat knob on one of the
available position (MIN-MED-MAX). If you wish to heat the room, set the thermostat to the
temperature level desired.
3) Select the economy (
tion selector.
To easily select the right temperature level, we suggest you to operate as follows:
Turn the thermostat to position MAX
When the temperature in the room has reached the required level, slowly turn the thermostat
knob anticlockwise until the heating light goes out.
The thermostat will then keep the temperature in the room at the selected level automatically.
C
ombined mode, (dehumidifying + heating)
1) Plug the appliance into a mains socket.
2) Check that the "tank full/no tank" warning light is off.
3) Select maximum (combi MAX) or minimum (combi MIN) power level. Consequently the
electrical power will be 1030 W or 1530 W.
4) It is possible to adjust the desired room humidity temperature °C by turning the humidistat
and the thermostat, (see chapters "How to dehumidify" and "How to heat")
Note: The appliance only stops completely when the level of humidity set is reached. If the
tank is full, the tankfull warning light comes on and the refrigerant circuit stops however
the heating function will continue to work.
Pagina 15
H o w t o d e h u m i d i f y
or
according to the desired dehumidifying power; the dehumidification
Stand-by indicator
Functions selector
light
= 1250 W) or maximum (
Thermostat indicator light
Tank control system
indicator light
= 2000 W) heating level on the func-
Thermostat
knob
15