Measurement A:
Installed length:
Minimum (hard): 218.5 mm (8.6 in)
Standard: 228.5 mm (9.0 in)
Maximum (soft): 233.5 mm (9.2 in)
A. Spring length
4. Tighten the locknut to the specified
torque.
Tightening torque:
42 Nm (4.2 m·kgf, 30 ft·lbf)
A
4-17
CAUTION:
_
Always tighten the locknut against the ad-
justing nut and tighten it to the specified
torque.
_