For Left Rear Piping - Heat Controller Energy Knight HMC30AS-1 Installation Instructions Manual

Wall mount mini-split system air conditioning/heat pump
Hide thumbs Also See for Energy Knight HMC30AS-1:
Table of Contents

Advertisement

Remove the front right side panel by the arrow.
B
The connector can be disconnected by pulling it
while pressing the connector's hook.
Remove the 1 screw
for fixing low panel.
Low panel
Remove the lower panel by the arrow.
C
Take care not to scratch the wall and mat to
drop.
CAUTION
When install, make sure
that the remaining parts
must be removed clearly
so as not to damage the
piping and drain hose,
especially power cord
and connecting cable.

For left rear piping

Route the indoor tubing and the drain hose in
A
the direction of rear left.
Main PCB
Lower panel
Drain hose
Insert the connecting cable into the indoor unit
B
from the outdoor unit through the piping hole.
Do not connect the cable to the indoor unit.
Make a small loop with the cable for easy
connection later.
Tape the tubing, drain hose and the connecting
C
cable. Be sure that the drain hose is located at
the lowest side of the bundle. Locating at the
upper side can cause drain pan to overflow
inside the unit.
Connecting
cable
Drain hose
NOTE: If the drain hose is routed inside the room,
insulate the hose with an insulation material
dripping from "sweating"(condensation) will not damage
furniture or floors.
*
Foamed polyethylene or equivalent is recommended.
Indoor unit installation
D
Hook the indoor unit onto the upper portion of the
installation plate.(Engage the three hooks of the
rear top and rear lower of the indoor unit with the
upper edge and lower edge of the installation
plate.) Ensure that the hooks are properly seated
on the installation plate by moving it left and right.
Installation plate
Indoor unit
7
Loop
Gas side
piping
Liquid side
piping
*
so that
Setting line
Three upper
hooks
Installation
plate
Three lower
hooks