Battery Connections
Use a 12-volt battery with an ampere-hour
rating of at least 35 Ah.
Be careful not to connect the battery in reverse polarity, as this will short circuit
the battery charging system. Always connect the positive (+) battery cable to
the battery terminal before connecting the negative (-) battery cable, so your
tools cannot cause a short circuit if they touch a grounded part while tightening
the positive (+) battery cable end.
A battery can explode if you do not
follow the correct procedure, seriously
injuring anyone nearby.
Keep all sparks, open flames, and
smoking materials away from the bat-
tery.
1. Connect the battery positive (+) cable to the starter solenoid terminal as
shown.
2. Connect the battery negative (-) cable to an engine mounting bolt, frame
bolt, or other good engine ground connection.
3. Connect the battery positive (+) cable to the battery positive (+) terminal as
shown.
4. Connect the battery negative (-) cable to the battery negative (-) terminal
as shown.
5. Coat the terminals and cable ends with grease.
ARTER SOLENOID
NEGATIVE
(-)
ERY CABLE
BAlTERY
CABLE
47