Power; Logger - Fluke 1730/US User Manual

Energy
Hide thumbs Also See for 1730/US:
Table of Contents

Advertisement

Power

 – In the Power mode you can get the values and a
live trend chart for each phase (A, B, C or L1, L2, L3) and
total as:
Active Power (P) in W
Apparent power (S) in VA
Non-active power (D) in var
Power factor (PF)
Use  (Fundamental/RMS) to toggle between full
bandwidth power values and power of the fundamental.
In the fundamental power screen you see these values:
Fundamental Active Power in W
Fundamental Reactive Power in var
Fundamental Apparent Power in VA
Displacement Power Factor (DPF) / cos
Note
In the user interface, the term Fundamental is
sometimes shortened to "Fund." or "h01."
Shop for Fluke products online at:

Logger

 – In Logger mode, you can:
Configure a new logging session
Review the data of an ongoing logging session in
memory
Review the data of a completed logging session (as
long as no new session has been started)
Push  and then  (Logging Sessions) to review a
logging session.
Logging Session Setup
When no logging session is active, push  to display the
Setup Summary screen for logging. This screen lists all
logging parameters such as:
Session name
Duration
Interval of the average calculation
Demand interval (not available for load studies)
Energy costs (not available for load studies)
Description
Go to Meter > Change Configuration to select between
Load Study and Energy Study. This Configuration screen
also contains the measurement configuration parameters
such as Topology, current range, voltage, and current
ratios. See page 28 for more information about
MyFlukeStore
www.
Function Selection Buttons
1.877.766.5412
.com
Energy Logger
25

Advertisement

Table of Contents
loading

This manual is also suitable for:

1730

Table of Contents