Payne PG8MVA Installation Instructions Manual page 45

Variable-speed induced-combustion 4-way multipoise gas furnace a series
Table of Contents

Advertisement

Table 13 - - Orifice Size and Manifold Pressure (In. W.C.) for Gas Input Rate (Con't.)
(Tabulated Data Based on 21,000 Btuh High- -Heat/14,500 Btuh for Low- -Heat Per Burner, Derated 4 Percent for Each 1000 Ft.
AVG. GAS
HEAT VALUE
ALTITUDE RANGE
AT ALTITUDE
FT. (M)
(BTUH/CU
FT.)
725
750
5001 to
775
6000
800
USA
825
(1524 to
850
1829)
875
900
AVG. GAS
ALTITUDE RANGE
HEAT VALUE
FT. (M)
AT ALTITUDE
(BTUH/CU FT.)
675
700
6001 to
725
7000
750
USA
775
(1829 to
800
2134)
825
850
AVG. GAS
ALTITUDE RANGE
HEAT VALUE
FT. (M)
AT ALTITUDE
(BTUH/CU FT.)
650
675
7001 to
700
8000
725
USA
(2134 to
750
775
2438)
800
825
AVG. GAS
ALTITUDE RANGE
HEAT VALUE
FT. (M)
AT ALTITUDE
(BTUH/CU FT.)
625
650
8001 to
675
9000
USA
700
(2438 to
725
2743)
750
775
600
9001 to
625
10,000
650
USA
675
(2743 to
700
3048)
725
* Orifice numbers 43 are factory installed
(305 M) Above Sea level)
SPECIFIC GRAVITY OF NATURAL GAS
0.58
Manifold
Orifice
Orifice
Pressure
No.
No.
High/Low
44
3.5/1.7
43
44
3.3/1.6
44
45
3.7/1.8
44
46
3.7/1.8
46
46
3.5/1.7
46
47
3.7/1.8
47
47
3.5/1.7
47
48
3.8/1.8
47
SPECIFIC GRAVITY OF NATURAL GAS
0.58
Manifold
Orifice
Orifice
Pressure
No.
No.
High/Low
44
3.5/1.7
43
44
3.3/1.6
44
45
3.7/1.8
45
46
3.6/1.7
46
46
3.4/1.6
46
47
3.6/1.7
47
47
3.4/1.6
47
48
3.7/1.7
48
SPECIFIC GRAVITY OF NATURAL GAS
0.58
Manifold
Orifice
Orifice
Pressure
No.
No.
High/Low
44
3.3/1.6
44
45
3.7/1.8
45
46
3.6/1.7
46
47
3.8/1.8
46
47
3.5/1.7
47
48
3.8/1.8
47
48
3.6/1.7
48
48
3.3/1.6
48
SPECIFIC GRAVITY OF NATURAL GAS
0.58
Manifold
Orifice
Orifice
Pressure
No.
No.
High/Low
45
3.7/1.8
45
46
3.6/1.7
46
47
3.8/1.8
46
47
3.5/1.7
47
48
3.7/1.8
48
48
3.5/1.7
48
49
3.8/1.8
48
46
3.6/1.7
46
47
3.7/1.8
47
47
3.4/1.6
47
48
3.6/1.7
48
48
3.4/1.6
48
49
3.7/1.8
49
45
0.60
0.62
Manifold
Manifold
Orifice
Pressure
Pressure
No.
High/Low
High/Low
3.2/1.5
43
3.3/1.6
3.4/1.6
44
3.5/1.7
3.2/1.5
44
3.3/1.6
3.8/1.8
45
3.8/1.8
3.6/1.7
46
3.7/1.8
3.8/1.8
46
3.5/1.7
3.6/1.7
47
3.7/1.8
3.4/1.6
47
3.5/1.7
0.60
0.62
Manifold
Manifold
Orifice
Pressure
Pressure
No.
High/Low
High/Low
3.2/1.5
43
3.3/1.6
3.4/1.6
44
3.5/1.7
3.8/1.8
44
3.3/1.6
3.8/1.8
45
3.7/1.8
3.5/1.7
46
3.6/1.7
3.8/1.8
46
3.4/1.6
3.5/1.7
47
3.6/1.7
3.8/1.8
47
3.4/1.6
0.60
0.62
Manifold
Manifold
Orifice
Pressure
Pressure
No.
High/Low
High/Low
3.4/1.6
44
3.5/1.7
3.8/1.8
44
3.3/1.6
3.7/1.8
46
3.8/1.8
3.5/1.7
46
3.6/1.7
3.7/1.8
47
3.8/1.8
3.4/1.6
47
3.6/1.7
3.7/1.8
48
3.8/1.8
3.5/1.6
48
3.6/1.7
0.60
0.62
Manifold
Manifold
Orifice
Pressure
Pressure
No.
High/Low
High/Low
3.8/1.8
44
3.3/1.6
3.7/1.8
46
3.8/1.8
3.4/1.6
46
3.5/1.7
3.6/1.7
47
3.7/1.8
3.8/1.8
47
3.5/1.7
3.6/1.7
48
3.7/1.8
3.4/1.6
48
3.5/1.7
3.7/1.8
46
3.8/1.8
3.8/1.8
46
3.5/1.7
3.6/1.7
47
3.7/1.8
3.8/1.8
47
3.4/1.6
3.5/1.7
48
3.6/1.7
3.8/1.8
48
3.4/1.6
0.64
Manifold
Orifice
Pressure
No.
High/Low
43
3.4/1.6
43
3.2/1.5
44
3.4/1.6
44
3.2/1.5
46
3.8/1.8
46
3.6/1.7
46
3.4/1.6
47
3.7/1.7
0.64
Manifold
Orifice
Pressure
No.
High/Low
43
3.4/1.6
43
3.2/1.5
44
3.4/1.6
45
3.8/1.8
46
3.8/1.8
46
3.5/1.7
47
3.8/1.8
47
3.5/1.7
0.64
Manifold
Orifice
Pressure
No.
High/Low
43
3.2/1.5
44
3.4/1.6
45
3.8/1.8
46
3.7/1.8
46
3.5/1.6
47
3.7/1.7
47
3.4/1.6
48
3.7/1.8
0.64
Manifold
Orifice
Pressure
No.
High/Low
44
3.4/1.6
45
3.8/1.8
46
3.7/1.7
46
3.4/1.6
47
3.6/1.7
48
3.8/1.8
48
3.6/1.7
45
3.7/1.8
46
3.6/1.7
47
3.8/1.8
47
3.5/1.7
48
3.7/1.8
48
3.5/1.7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pg8jva

Table of Contents