Maintenance - Kidde KN-COB-IC User Manual

120v ac wire-in 9v battery backup interconnectable with other kidde alarms
Hide thumbs Also See for KN-COB-IC:
Table of Contents

Advertisement

7. Model KN-COP-IC (with digital display)
Operating Characteristics
The following table illustrates the possible digital displays, describes the
audible alarm patterns, and the recommended actions to take.
Operating and Alarm Characteristics
LED Display Shows
Alarm Sound Unit Status
Brief "888" along
4 quick beeps,
with any number
5 seconds
between 100 and 300.
silence,
Red LED flashes with beeps.
repeated once
Green and amber LED's on.
Steady "0"
None
Green LED
constantly on.
"Lb" flashes
One quick
alternately with
beep every
any number.
15 seconds
Red LED flashes
every 15 seconds.
A steady display of
4 quick beeps,
CO concentration
5 seconds
from 30-999. Red
silence,
LED flashes with beeps. Amber
repeating
LED shows initiating alarm.
Steady "CO"
4 quick beeps,
Red LED flashes with
5 seconds
beeps. Amber LED
silence,
shows initiating alarm
repeating
"FirE"
3 long beeps,
Red LED flashes
1 second
with beeps
silence,
repeating
Steady "Err"
One quick
Red LED flashes every
beep every
30 seconds
30 seconds
No display alternating
4 quick beeps,
with display of CO
5 seconds
concentration every 60
silence,
seconds. Red LED
repeating
flashes with beeps
every 60 secs
No display alternating
None
with "0" every 60
seconds.
Green LED flashes
every 7 seconds
Recommendation
Self checking when
None – CO has not
AC powered (Test
been detected.
button was pressed
Numbers shown for
or unit was first
test purposes only
powered)
Normal AC
None
operation (sensing
no CO) and with a
good battery
AC powered and
Install or replace 9V
low or missing
battery.
battery
Alarm condition.
Refer to "What to do
Dangerous
When the Alarm
concentrations of
Sounds" (inside front
CO detected
cover)
Interconnected CO
Refer to "What to do
alarm warning of a
When the Alarm
CO condition
Sounds" (inside front
cover)
Interconnected
Evacuate by your
smoke alarm
escape plan
warning of a
smoke/fire condition
Unit malfunction
Replace battery.
If "Err" continues,
unit has malfunc-
tioned. Replace
immediately. Unit will
not respond CO
Alarm condition
Refer to "What to do
powered on battery
When the Alarm
backup. Dangerous
Sounds" (inside front
concentrations of
cover).
CO detected
Replace battery
Normal operation
Verify AC power is
after first 4 minutes
restored as soon as
of 9 V battery
possible to conserve
operation. Unit
battery.
monitoring for CO
Replace battery
7. Model KN-COP-IC (with digital display)
Operating Characteristics
Peak Level Memory (model KN-COP-IC only)
When the Peak Level button is pressed and held, the display shows the
highest CO reading taken by the CO alarm since its last reset or power
up. The Peak Level display feature will display levels between 11-999
PPM. Although the Peak Level feature will display levels below 30 PPM,
these levels will not result in an alarm no matter how long the device is
exposed to these levels. The Peak Level feature is helpful in identifying if
you have had a CO reading since resetting the alarm.
Concentrations of CO between 1 and 30 PPM can often occur in nor-
mal, everyday conditions. Concentrations of CO below 30 PPM may be
an indication of a transient condition that may appear today and never
reappear. Some CO conditions may start out as low level leaks but could
develop into CO concentrations that may become harmful.
Peak Level Memory Reset
Press the Peak Level button; with the button still pressed, press the
Test/Reset button for two seconds and release. The number on the dis-
play will turn to "0", the memory will be cleared and the alarm will
begin monitoring for CO. The Peak Level memory is also reset when the
unit loses power.

8. Maintenance

NOTE: This unit is sealed. The cover is not removable.
Due to the loudness of the alarm, we suggest that you place your
fingers over the sounder opening while testing your alarm.
CAUTION: Continuous exposure to the high sound level of this
alarm over an extended period of time may cause hearing loss.
Testing
To test the alarm, press the Test/Reset button. If the unit is operating
properly, you should hear 4 quick beeps – followed by 5 seconds of
silence – followed by 4 quick beeps. (For model KN-COP-IC with digi-
tal display: The display will show three "eights" and then show a num-
ber – usually around 200). The red LED will flash along with the beeps
and the amber LED will illuminate. Within several seconds the unit will
return to monitor for CO.
If interconnected to Kidde smoke alarms, pressing the Test/Reset button
on the CO alarm will have no effect on the smoke alarms. The smoke

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kn-cop-ic

Table of Contents