Kidde KN-COB-BCA User Manual

Battery operated co alarm without digital display/battery operated co alarm with digital display and peak level memory

Advertisement

Ca r b o n Mo nox i d e
Battery operated CO alarm
without Digital display
MODEL: KN-COB-BCA
ASSEMBLY: 9CO5
For questions concerning your Carbon Monoxide Alarm,
please call our Consumer Hotline at 1-800-880-6788.
Please have the following information ready when calling:
CO Alarm Model Number
CO Alarm Assembly Number
Date of Manufacture
Date of Purchase:
Where Purchased:
ATTENTION Please take a few minutes to thoroughly read this manual which
should be saved for future reference and passed on to any subsequent owner.
B a t t e ry Operated
A l a rm
U s er's Guide
(Located on the back of alarm):
(Located on back of alarm):
(Located on back of alarm):
Battery operated CO alarm
With Digital Display and
Peak Level memory
MODEL: KN-COPP-BCA
ASSEMBLY: 900-0146
810-2263
Rev A

Advertisement

Table of Contents
loading

Summary of Contents for Kidde KN-COB-BCA

  • Page 1 Battery operated CO alarm Battery operated CO alarm without Digital display With Digital Display and Peak Level memory MODEL: KN-COB-BCA MODEL: KN-COPP-BCA ASSEMBLY: 9CO5 ASSEMBLY: 900-0146 For questions concerning your Carbon Monoxide Alarm, please call our Consumer Hotline at 1-800-880-6788.
  • Page 2: Table Of Contents

    ......Your new Kidde CO alarm has a five year limited warr a n t y. Please Troubleshooting Guide .
  • Page 3: Kidde Product View

    Kidde Product Vi e w Kidde Product Vi e w non-digital 9CO5 model 900-0146 Digital display model...
  • Page 4: Quick Set Up

    Upper Levels of Home DINING KITCHEN BEDROOM BEDROOM LIVING ROOM BEDROOM Your Kidde CO Alarm is now operational. Note: Basement Levels of Home Seven (7) years after initial power up, this unit will "chirp" every FURNACE 30 seconds to indictate that it is time to replace the alarm. After...
  • Page 5: Installation Instructions

    . ) Figure 1 Dust, grease and household chemicals can affect the sensor. 3 . Hook the Kidde CO Alarm unit over the screws onto keyholes in back of unit. • Keep out of damp and humid areas such as the bathroom.
  • Page 6: Features And Operations

    The display should change to the Digital Display - Shows CO level in PPM normal display (see figure 3) approximately Your Kidde CO alarm continuously displays a digital readout of Figure 4 30 seconds after pressing the test/reset button.
  • Page 7 30 PPM or a CO alarming device immediately. that is in alarm. Refer to page 18 for more details. Note: Your Kidde CO Alarm will NOT monitor CO levels while an error warning is being displayed. Low Battery If the batteries become “low”, the alarm will...
  • Page 8: Test Reset Button/Lights

    Kidde C O Alarm.
  • Page 9: Battery Installation/Replacement

    B a t t e ry Replacement/Installation Instru c t i o n s Since batteries are not installed in the unit at the factory, you will To install or replace the batteries in your Kidde unit please per- need to install them.
  • Page 10: What To Do If The Alarm Sounds

    P a rt Four – What to do When the What To Do If The Alarm Sounds ( c o n t i n u e d ) A l a rm Sounds Symptoms of CO Poisoning Carbon Monoxide Alarm Procedure The following common symptoms are related to carbon monoxide poisoning and should be discussed with ALL members of the WARNING: Actuation of the CO Alarm...
  • Page 11: Caring For Your Kidde Battery Powered Co Alarm

    To keep your CO alarm in good working order, please s u re s to low levels may cause symptoms, as well as short - t e rm exposures to high levels. This Kidde unit has a time-weighted follow these simple steps: a l a rm - the higher the level of carbon monoxide present, the sooner •...
  • Page 12: Troubleshooting Guide

    Caring for your Kidde Battery Powered Troubleshooting Guide CO Alarm (continued) Symptom Problem Action Move the CO alarm and place in another location prior to per- 1 chirp every 30 sec- forming any of the following: See pages 16-17. onds with a red LED Batteries are low •...
  • Page 13: Frequently Asked Questions

    Wall Mounting Te m p l a t e F requently Asked Questions If you are going to mount your Kidde CO Alarm to the wall, you may use this template for exact placement of the two wall mount How many CO alarms do I need? screws provided.
  • Page 14: Product Specifications

    : Electrochemical carbon monoxide sensor SENSOR M ATERIAL AND WORKMANSHIP FOR A PERIOD OF FIVE (5) YEARS FROM DAT E : Each Kidde CO Alarm is calibrated to a CO con- ACCURACY OF PURCHASE. THE MANUFACTURER’S LIABILITY HEREUNDER IS LIMITED TO centration of 150 ppm (+/-25 ppm) in air, at 80°F...
  • Page 15: Notes

    Important: Do not remove back cover. Back cover removal will void warranty. Your Kidde Carbon Monoxide Alarm is not a substitute for pro p e rt y, d i s- a b i l i t y, life or other insurance of any kind. Appropriate insurance cov- erage is your responsibility.

This manual is also suitable for:

Kn-copp-bca

Table of Contents