3. BATTERY CONNECTIONS (for DC electric starter)
Use a 12 volt battery with an ampere-hour
rating of at least 18 AH.
connect
the battery positive (+) cable to the starter solenoid terminal as
shown.
Connect the battery negative (-1 cable to an engine mounting bolt, frame
bolt, or other good engine ground connection.
Check the battery cable connections
to be sure the cables are tightened
and free of corrosion.
Remove any corrosion and coat the terminals
and
cable ends with grease.
mm
Batteries
produce
explosive
gases.
Keep sparks,
flames,
and
cigarettes
away.
Always
shield the eyes when
working
near batteries.
CAUTION:
Be careful
not to connect
the battery
in reverse polarity,
as this
will short circuit
the battery
charging
system
and trip the circuit
breaker.
A regulator rectifier unit supplies charging current to the battery on DC
starter-equipped
engines.
NEGATIVE (-1 -
BATTERY CABLE
REGULATOR
RECTIFIER
POSITIVE (+I
BATTERY CABLE
/
STARTER
'SOLENOID