Kohler K-1969 Homeowner's Manual page 10

Bath with airjets
Hide thumbs Also See for K-1969:
Table of Contents

Advertisement

Available languages

Available languages

Troubleshooting (cont.)
Symptoms
8.
Blower motor operates,
air bubbles are formed,
zone controls work, but
variable speed feature
does not work.
9.
Blower motor won't turn
off when the On/Off
button on user keypad is
pressed.
10. A zone does not produce
air bubbles but another
zone operates normally.
11. Surge mode does not
work.
1159617-5-B
Probable Causes
B. Airjets are plugged.
C. Check valve does not work.
D. Blower motor does not work.
E. Control does not work.
A. Blower motor inlet is blocked.
B. Loose, disconnected, or
damaged wiring harness.
C. User keypad does not work.
D. Blower motor does not work.
E. Control does not work.
A. User keypad does not work.
B. Loose, disconnected, or
damaged wiring harness.
C. Control does not work.
A. Zone is not selected.
B. Butterfly valve does not work.
C. Loose, disconnected, or
damaged wiring harness.
D. User keypad does not work.
E. Control does not work.
A. User keypad does not work.
B. Control does not work.
Recommended Action
B. Wet a soft, non-abrasive cloth with
white vinegar and wipe the
plugged hole. Rinse the area with
clean water to avoid long-term
exposure of the vinegar to the bath
or airjet surface.
C. Replace the check valve. Refer to
your installer or wholesale dealer.
D. Replace the blower motor. Refer to
your installer or wholesale dealer.
E. Replace the control. Refer to your
installer or wholesale dealer.
A. Clean blower motor inlet.
B. Check wiring for proper
connections. Replace the wiring
harness if necessary. Refer to your
installer or wholesale dealer.
C. Replace the user keypad. Refer to
your installer or wholesale dealer.
D. Replace the blower motor. Refer to
your installer or wholesale dealer.
E. Replace the control. Refer to your
installer or wholesale dealer.
A. Replace the user keypad. Refer to
your installer or wholesale dealer.
B. Check wiring for proper
connections. Replace the wiring
harness if necessary. Refer to your
installer or wholesale dealer.
C. Replace the control. Refer to your
installer or wholesale dealer.
A. Select the zone according to the
instructions in "User Keypad and
Bath with Airjets Modes/Features."
B. Replace the butterfly valve. Refer to
your installer or wholesale dealer.
C. Check wiring for proper
connections. Replace the wiring
harness if necessary. Refer to your
installer or wholesale dealer.
D. Replace the user keypad. Refer to
your installer or wholesale dealer.
E. Replace the control. Refer to your
installer or wholesale dealer.
A. Replace the user keypad. Refer to
your installer or wholesale dealer.
B. Replace the control. Refer to your
installer or wholesale dealer.
10
Kohler Co.

Advertisement

Table of Contents
loading

Table of Contents