Weber SP 100 NG Owner's Manual page 17

Natural gas barbecue
Table of Contents

Advertisement

Step 14
Check for gas leaks
DANGER
Do not use an open flame to check for
gas leaks. Be sure there are no sparks or
open flames in the area while you check
for leaks. This will result in a fire or
explosion which can cause serious bodily
injury or death and damage to property.
WARNING: You should check for gas leaks every
time you disconnect and reconnect a gas fitting.
Note - All factory made connections have been
thoroughly checked for gas leaks. The burners have
been flame tested. As a safety precaution you should
recheck all fittings for leaks before using your Weber
Gas Barbecue. Shipping and handling may have
loosened or damaged a gas fitting.
WARNING: Perform these leak checks even if your
barbecue was dealer or store assembled.
You will need: a soap and water solution and a rag or
brush to apply it.
To perform leak checks: Slide back the collar of the
quick disconnect. Push male fitting of the hose into the
quick disconnect, and maintain pressure. Figure 15 (a).
Slide the collar closed. Figure 15 (b). If it does not
engage or lock, repeat procedure. Gas will not flow
unless the quick disconnect is properly engaged.
(a)
To barbecue
Male fitting
Turn on gas supply.
Check for leaks by wetting the connections with the
soap and water solution and watching for bubbles. If
bubbles form or if a bubble grows there is a leak.
Note - Since some leak test solutions, including soap
and water, may be slightly corrosive, all connections
should be rinsed with water after checking for leaks.
WARNING: Do not ignite burners when leak checking.
Locking shut off
Outside house wall
Collar
(b)
Quick disconnect
engaged
Figure 15
Check:
a) Hose to manifold connection. Figure 16 (a).
WARNING: If there is a leak at connection a,
retighten the fitting with a wrench and recheck for
leaks with soap and water solution.
If a leak persists after retightening the fitting, turn
OFF the gas. DO NOT OPERATE THE BARBECUE.
Contact Weber-Stephen Customer Service.
b) Valves to manifold connections. Figure 16 (b).
c) Hose to quick disconnect connection. Figure 16 (c).
WARNING: If there is a leak at connections b or c,
turn OFF the gas. DO NOT OPERATE THE
BARBECUE. Contact Weber-Stephen Customer
Service.
When leak checks are complete, turn gas supply OFF at
the source and rinse connections with water.
Figure 16
17
(a)
(b)
(c)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sp-100

Table of Contents