Step 10
Install igniter
Note - The igniter wires are already attached to the Gas
Catcher Ignition Chamber and the igniter. This was done to
factory test the ignition system.
The igniter lock nut is on the igniter.
Insert the top of the igniter up through the large part of
the keyhole in the frame brace. Figure 11 (b). Loosen the
igniter lock nut and slide the igniter into the small part of
the keyhole. Figure 11 (c). Tighten the igniter lock nut.
Figure 11.
Note - If the igniter works loose, carefully tighten the igniter
lock nut with an adjustable wrench or pliers.
Figure 11
Frame brace
(a)
Frame brace
Keyhole in
frame brace
Igniter lock nut
(c)
Small part of keyhole
in frame brace
Step 11

Install gas supply

General Specifications for Piping

Note - Contact your local municipality for building
codes regulating outdoor gas barbecue installations.
In absence of Local Codes, you must conform to the
latest edition of ANSI Z223.1. WE RECOMMEND THAT
THIS INSTALLATION BE DONE BY A PROFESSIONAL.
Some of the following are general requirements taken
from ANSI Z223.1, for gas supply installations. Refer to
ANSI Z223.1 latest edition for complete specifications.
This barbecue is designed to operate at 7 inches of
water column pressure (.2526 psi).
A manual shut-off valve must be installed outdoors,
immediately ahead of the quick disconnect.
An additional manual shut-off valve indoors should be
installed in the branch fuel line in an accessible
location near the supply line.
The quick disconnect connects to a 3/8 inch NPT
thread from the gas source. The quick disconnect
fitting is a hand-operated device that automatically
shuts OFF the flow of gas from the source when the
(b)
barbecue is disconnected.
The quick disconnect fitting can be installed
horizontally, or pointing downward. Installing the fitting
with the open end pointing upward can result in
collecting water and debris.
The dust covers (supplied plastic plugs) help keep the
open ends of the quick disconnect fitting clean while
disconnected.
Pipe compound should be used which is resistant to
the action of natural gas when connections are made.
The outdoor connector must be firmly attached to
rigid, permanent construction.
WARNING: Do not route the 12 foot hose under a
deck. The hose must be visible.