Installing the Logs and Embers
Bottom Logs
The M38ODV-ST is supplied with five (5) fibre logs. The two large
bottom logs (logs "A" and "B") are mounted on the burner grate by
placing them into the slots.
Top Logs
Place logs "C" and "D" into their mating positions on the large logs as
shown in Figure 12a below. Log "E" is mounted on top of logs "C" and
"D" as shown in Figure 12b.
WARNING:
WARNING:
WARNING:
WARNING:
WARNING: If logs are not placed properly, excessive
sooting will result.
Figure 12a. Log Installation.
Figure 12b. Completed Installation.
XG0128
Installation
Removing and Installing the
Removing the door surround:
The door surround is held in place by two metal clips at the top, and
one magnet on each side. To remove the surround, pull the bottom
outwards and lift upwards until the slots "A" are clear of tabs "B" in the
door. You may need to use a flat screwdriver to pull the door surround
outwards. (See figure 13).
Magnet
Pull bottom of
door surround
outwards and
upwards.
Removing the door:
To install/remove the glass door simply attach/remove the four (4)
machine screws, align tabs at the bottom of the door with the slots in
the bottom door rail (See figure 14). Ensure that a good seal is
maintained.
M38ODV-ST Direct Vented Fireplace
Door
Slot 'A'
Tab 'B'
Door surround
Figure 13. Removing door surround.
Machine Screws
Door Rail
Tabs
Figure 14. Installing Glass Door.
Glass door
and frame