Montigo L52DF-ST Installation, Operation & Maintenance Manual page 8

Gas fireplace
Table of Contents

Advertisement

L52DF(O)-ST See-thru Gas Fireplace
PEXT
PXT-10
* For venting MIN 1" clearance to all vertical combustibles,
MIN 2" to all horizontal combustibles.
Figure 15. Straight, vertical venting showing required PXT-10 adaptor
(supplied with the PVTK-1 termination).
Figure 16. Vertical venting with 1 offset (1 offset= two 90° bends).
NOTES:
All dimension lengths for vertical or horizontal runs are
measured from centre of the vent pipe.
Venting runs must fall within the limits set by the venting
graph (see Figure 7b).
Page 8
Installation
PEXT
32'
Figure 17. Vertical venting with 2 offsets (1 offset= two 90° bends).
Reduced Vertical Installation
(Available on Linear Power Vent models ONLY)
It is possible to reduce vertical vent runs from 5"/8" venting to 4"/7"
venting. Reduced vertical venting may only be used when the Linear
(In-line) Power Vent is required. This is commonly due to longer than
normal vent runs or unusually long horizontal Vent runs.
Figure 18. Reducing Vertical Vent from 5/8" to 4/7".
f i r e f e a t u r e
Part No. XG0711