Honeywell ERX User Manual page 65

Electronic pressure recorder
Table of Contents

Advertisement

Item
Item Name & Description
789
Modem AT Enable
Selection to that determines the type of call-in initiated by the recorder.
Code
0
Default:1
790
Parameter used to set the amount of time to leave the system powered up after a call-in
(allowing time for the host to call-back). Time is specified in minutes.
Default: 15 minutes
791
Call-out Start Time
Parameter used to set the time of day to start the call-out cycle when using modem power
control.
Default: 00 00 00
792
Call-out Repeat Interval
Parameter used to set the amount of the time to wait from the beginning of the current
interval until repeating the call-out window set by the call-out keep alive time, specified
in minutes.
Default: 0 minutes
793
Call-out Keep Alive Time
Parameter used to set the time of day to start the call-out cycle when using modem power
control.
Default: 0 minutes
807
P3 High/High Alarm Limit
The high/high alarm feature adds an additional alarm notice, that is, in addition to the
normal high alarm limit set by item 455 and even higher alarm limit may be set, which
creates a two-step alarm notification.
Default: 333.00
808
P3 Low/Low Alarm Limit
The low/low alarm feature adds an additional alarm notice, that is, in addition to the
normal low alarm limit set by item 456 and even lower alarm limit may be set, which
creates a two-step alarm notification.
Default: -1.00
809
P3 High/High Alarm
Code
Default: 00000000
11111111
810
P3 Low/Low Alarm
Code
Default: 00000000
11111111
Value
Call-in via alarm pulse
Call-in via AT commands
Value
No alarm
Alarm
Value
No alarm
Alarm
65