4.3 INSTALLING THE DUCTS IN THE WALL

MANUFACTURER'S RECOMMENDATION.
BEFORE UNDERTAKING ANY INSTALLATION OF DUCTS INTO WALL, WE
RECOMMEND THAT YOU CONSULT A KNOWLEDGABLE PROFESSIONAL.
A) You do not need to use window kit adapter. Mount one end of the exhaust duct into a hole
of 5.6"/14.22cm in diameter in the wall; attach the other end to the back of the unit (same
as above).
B) Use the exhaust outlet wall covers to cover the holes in the wall when the unit is not in use.
NOTE:
Mounting the exhaust pipe
The supplied exhaust hose can extend from 5.75"
to 63" / 40cm to 160cm for mounting. It is
recommended that you use the shortest possible
length of hose.
Take care to prevent any kind of bend in the
middle of the exhaust hose, as this will trap hot
exhaust air, which will radiate back into the
room and affect the cooling function of the unit
(Fig. 10).
WARNING
The length of the exhaust pipe is specially designed
according to the specification of this product. Do not
replace or extend it with your own hose as this could
cause the unit to malfunction (Fig. 11).
C) After installing the ducts, plug in the unit and turn the unit on.