6 - Appendix
Word Clock In/Out
House Sync
Generator
A master word clock generator is preferable for larger digital setups.
Word Clock In: Receives word clock (sample clock) from another digital device such as
a digital video deck, digital recorder or digital mixer.
Word Clock Out: Sends word clock (sample clock) to another digital recorder. Word
clock is always output, whether it is generated by the internal clock or passed through
from the word clock input.
75 On/Off: Termination for the word clock input can be switched on or off in the
Sync Card menu of the PatchMix DSP application. Normally word clock termination
should be left on. If you have problems with a weak word clock signal, try turning
termination off. See
Word Clock
The diagram below shows the proper way to connect and terminate a serial word clock
chain. Using a BNC "T" connector ensures that word clock is precisely in phase for
both devices. The middle device has termination turned Off and the last device in the
word clock chain has termination turned On.
ADAT Optical
or AES Digital
E-MU 1010 CARD
SYNC CARD
This diagram shows the proper way to connect word clock if you don't have a multi-output
word clock generator. The last device in a Word Clock chain should have Termination ON.
118
Digital
Device 1
Digital
Device 2
Termination.
Digital Mixer
ADAT Optical
Word Clock Termination OFF
AES
Word Clock Termination ON
Digital
Device 3
Digital
Device 4
Word Clock
T - connector
IN
IN
When the MicroDock
is connected to the 1010
PCI card, the digital I/O
on the PCI card is
disabled. Use the digital
I/O on the MicroDock.