Scytek electronic Astra 1000RS Series Product Manual page 21

Automatic/manual transmission with seperate lock/unlock buttons remote start system
Hide thumbs Also See for Astra 1000RS Series:
Table of Contents

Advertisement

Momentary operation provides an output for as long as the transmitter button is pressed.
Timed operation provides an output that turns on for 10 seconds each time the transmitter button is
pressed. If the button is pressed again during the 10 seconds, the output will turn off.
Latched operation provides an output that turns on when the transmitter button is pressed and remains
on until the transmitter button is pressed again.
6. Unlock with Aux 1. Selects whether the doors should unlock when you press the trunk button.
7. Start in Valet Mode. Selects if vehicle should start when in Valet.
8. Lock after Start. Selects if doors should lock upon Remote Start.
9. Lock after Shutdown. Selects if doors should lock when Remote Start shuts down.
10. Engine Run Time. Selects between 15 or 25 minutes for the remote start run cycle.
11. Automatic Start Mode. Select to automatically start vehicle every 1 or 2 hours.
12. Tachless Sense Crank Time. Selecting engine crank time automatically selects the tachless mode
and one of three crank times.
If the normal engine crank time is too short increase the time by selecting one of the two additional
extended crank time options.
Normal -
Extended -
Super Extended - 1.4Sec.
Tachless Mode. Determines the engine status using an advanced software routine, without requiring
connection to the vehicle's tachometer. Tachless operation may not be compatible with some vehicles
or in severe temperatures, in which case the tach wire must be connected.
13. Remote Start Program. This dual program branch sets the engine mode for Gas or Diesel, and
learns the vehicle's RPM threshold. Learning the RPM threshold automatically selects the RPM
monitor mode. For installation into a diesel equipped vehicle, first set the engine type to diesel
before learning RPM.
Tach Monitor Mode. Monitors the vehicle's tach wire (or a fuel injection wire) in real-time to determine
engine status and adjust starter crank time automatically. If programmed for Tach Monitor, the vehicle's
tach signal will have to be learned before initial operation (see below).
RPM Learn. Start the engine, enter Branch 13, the LED light should be flashing to confirm tach signal.
Press Button 1 to learn the vehicle's tach signal. The siren will chirp and the LED will stop flashing to
confirm learning of the tach signal and. The siren will chirp four times and the LED will flash four times
if the tach signal was not learned, engine sense mode will not be changed.
Gas Engine. Sets the engine type for Gasoline.
Diesel Engine. Sets the engine type for Diesel and monitors the glow plug input to make sure the glow
plugs are warm before cranking the starter. If the glow plug wire is not connected, the built-in timer
waits 15 seconds before automatically cranking the starter.
14. Ignition 2 Relay Program. Selects one of three operating modes for the Ignition 2 relay output:
Ignition 2, Accessory 2, or Starter 2.
0.8Sec.
1.0Sec.
Astra 1000RS Series - Page 17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Astra 1000rs-2w

Table of Contents