To change freezer light
NOTE: Some models have LED interior lighting and service
should be performed by a qualified technician.
1. Unplug refrigerator power cord form outlet.
2. Using a flat instrument, gently pry the lamp cover loose
in the front as shown. Rotate downward to remove the
rear tabs.
3. Make sure the bulb is cool to the touch. Turn the bulb
counterclockwise to remove.
4. Replace with a new 60-watt appliance bulb.
5. Insert tabs on back of cover into slots in freezer ceiling.
Push cover up to snap front into place.

3-7 MULTI DUCT

1. Remove the upper and
lower Caps by using a
flat screwdriver, and
remove 2 screws.
(Figure 17)
2. Disconnect the lead wire
on the bottom position.

3-8 MAIN PWB

1) Loosen the 4 screws on the PWB cover.
2) Remove the PWB cover
3) Disconnect wire harness and replace the main PWB in
the reverse order of removal.

3-9 DISPENSER

1) Disconnect funnel and
button assembly by
pulling down and
forward.