Display; Procedure 1 External Monitor Check; Procedure 2 Test Program Check; Procedure 3 Connector Check And Replacement Check - Toshiba Satellite M40 Maintenance Manual

Personal computer
Hide thumbs Also See for Satellite M40:
Table of Contents

Advertisement

2 Troubleshooting
2.7

Display

To check if the computer's display is defective or malfunctioning, follow the troubleshooting
procedures below as instructed.

Procedure 1 External Monitor Check

Procedure 2 Test Program Check

Procedure 3 Connector Check and Replacement Check

Procedure 1 External Monitor Check

Connect an external monitor to the computer's externa l monitor port, then boot the computer.
The computer automatically detects the external monitor even if resume mode is enabled.
If the external monitor works correctly, the internal LCD, LCD/FL cable, or FL may be
faulty. Go to Procedure 3.
If the external monitor appears to have the same problem as the internal monitor, the system
board may be faulty. Go to Procedure 2.

Procedure 2 Test Program Check

Insert the diagnostics bootable CD in the computer's CD ROM, turn on the computer and run
the test. See Chapter 3 for information on how to perform the test.
If an error is detected in the test, go to Procedure 3. If no error is detected, the display itself
is normal.

Procedure 3 Connector Check and Replacement Check

The display unit has an LCD module, Fluorescent lamp (FL), panel close switch and FL
inverter board. Any of the components or their connections may be defective. Disassemble
the computer following the steps described in Chapter 4, then perform the following checks:
(1)
If the FL does not light, perform Check 1.
(2)
If characters or graphics are not displayed normally, perform Check 5.
(3)
If the FL remains lit when the display is closed, the panel close switch may be
defective. Perform Check 8.
Check 1
Make sure the following cables have been firmly connected to the system
board and FL inverter board.
FL
If any of the cables is loose or off, reconnect it firmly and return to
Procedure 3. If there is still an error, perform Check 2.
Check 2
The LCD/FL cable may be faulty. Replace it with a new one and return to
Procedure 3. If there is still an error, perform Check 3.
2-16
FL inverter board
HV cable
Satellite M40/M45 TECRA A4 dynabook Vx/4 Maintenance Manual
System board
LCD/FL cable

2.7 Display

CPU