GLASS CARE
Glass Replacement
The glass used for the Ladera™ fireplace is a high
If the glass breaks, it must be replaced with
an identical ceramic glass. Tempered glass
or ordinary glass will not withstand the high
temperatures of the Ladera fireplace. Replace-
ment glass should be purchased from a IHP
dealer (see "Replacement Parts", Page 22).
DO NOT OPERATE THE UNIT WITH CRACKED
OR BROKEN GLASS.
Glass Cleaning
The Ladera fireplace is designed to keep the
glass clean under normal operating conditions.
If the Ladera fireplace is operated continuously
with the combustion air controls closed, the
glass will tend to get dirty unless the fuel, firebox
and glass are maintained at hot temperatures
(see "Refueling For Best Performance"). To
clean the glass, there are a number of specially
designed cleaners. Your IHP dealer can recom-
mend a suitable cleaner which is available in
your area. Regular household glass cleaners
will not clean creosote. Do not use abrasives
such as steel pads, steel wool or oven cleaner
as they will scratch the glass.
DO NOT USE CHEMICAL GLASS CLEANERS
THE PAINT TO PEEL.
CAUTION : DO NOT ALLOW WINDOW CLEANER
TO GET IN CONTACT WITH DOOR GASKET OR
PAINT ON FACADE OR DOOR. ONCE CLOSED,
CONTACT OF GLASS CLEANER WITH THE
FIREPLACE FACADE CAN PROVOKE PAINT
PEELING OFF.
Marginal Location
Wind Direction
Location
Not
Recommended
Outside Air Intake
Facing the Wind
Figure 6

Gasket Replacement

Remove the door from the unit (see Page 6)
and lay it on a clean unabrasive surface. To
replace the gasket, first remove all of the old
gasket and gasket cement. Make sure that the
surface is totally clean before applying new
cement (a high temperature silicone caulking
rated at 500° F [260° C], is suitable) or adhesion
problems may result. Apply gasket cement to
the gasket channel and install the new gasket.
This replacement part is available from your IHP
dealer in the following dimensions:
Gasket
Length* Dimensions
Around
69
Glass
(1753)
(25 x 4.8)
On Door
73
Frame
(1854)
(19.5)
Table 1
*NOTE: Inches (millimeters)

FIREPLACE INSTALLATION

Locating The Ladera Fireplace

The best location to install your fireplace is
determined by considering the location of
windows, doors, and the traffic flow in the room
where the fireplace is located, allowing space
in front of the unit for the hearth extension and
the mantel, and taking into consideration the
location of the hot air ducts (optional), outside
air kit (optional) and chimney.
Location Recommended
If possible, you should choose a location where
the chimney will pass through the house without
cutting floor or roof joists (see fireplace dimen-
sions Page 9).
for the fireplace. The adequacy of the floor
can be checked by first estimating the weight
of the fireplace system. Weights are given
on Page 22. Note the floor construction and
consult your local building code to determine
if additional support is needed.
The Ladera fireplace may be installed directly
Part No.
on the floor or on a raised base (for proper
guidelines, refer to "Hearth Extension Require-
PR-SR1685H
ments") and a minimum of 6'8" (2 m) measured
from the base of the appliance to the ceiling
is required.
PR-SR1823O
When selecting the location, the chimney outlet
position and the direction of the wind are impor-
tant factor affecting the chimney performance.
To allow a maximum draft and to reduce wind
turbulence, the chimney must:
trees or any other obstructions that may
cause wind turbulence and back drafts in
the chimney.
sible. NOTE: A maximum of 2 offsets is
allowed.
Location
Not
Recommended
-
7