Epa wood-burning fireplaces

Advertisement

Quick Links

Shown with louver kit installed
A French manual is available upon request. Order P/N 506223-27.
Ce manuel d'installation est disponible en francais, simplement en faire
la demande. Numéro de la pièce 506223-27.
THIS UNIT REQUIRES THE INSTALLATION OF A
FINISHING KIT. SEE "PARTS REQUIRED"
SECTION FOR DETAILS
Fireplace, Also For Use In
Manufactured Homes With Solid Fuel Only.
• Hot! Do not touch! The glass and
surfaces of this appliance will be hot
during operation and will retain heat
for a while after shutting off the appli-
ance. Severe burns may result.
• Carefully supervise children in the
same room as appliance.
• If small children are present in the home, it is
recommended that this appliance be fitted with
an adjustable safety gate or barrier screen.
Shown with clean face kit installed
WARNING
Listed to standards:
ULC-S610 & UL-127
Report No. 3011202
EPA Cert. No. 537
PIBRENTLV REV. 3 05/2013
INSTALLATION AND

OPERATION INSTRUCTIONS

Brentwood™ LV
EPA Wood-Burning Fireplaces
P/N 506023-13 REV. C 05/2013
MODEL
Brentwood LV
This installation manual will enable you to obtain a safe, efficient and
dependable installation of your fireplace system. Please read and
understand these instructions before beginning your installation.
Do not alter or modify the fireplace or its components under any circum-
stances. Any modification or alteration of the fireplace system, including
but not limited to the fireplace, chimney components and accessories,
may void the warranty, listings and approvals of this system and could
result in an unsafe and potentially dangerous installation.
IHP wood-burning fireplaces are designed for use as a supplemental
heater. They are not intended for continuous use as a primary heat
source.
SAVE THESE INSTRUCTIONS
FOR FUTURE REFERENCE
• The fireplace cannot be operated without a door
or firescreen. Consult your dealer to select the
correct door or firescreen.
• Important! To assure proper alignment of glass
doors: Install this fireplace in a square and
plumb condition, using shims as necessary at
sides and/or bottom.
• Install the fireplace only as described in these
instructions.
WARNING

Advertisement

Table of Contents
loading

Summary of Contents for Lennox Hearth Products BRENTWOOD LV

  • Page 1: Operation Instructions

    Brentwood™ LV EPA Wood-Burning Fireplaces P/N 506023-13 REV. C 05/2013 MODEL Brentwood LV This installation manual will enable you to obtain a safe, efficient and dependable installation of your fireplace system. Please read and understand these instructions before beginning your installation.
  • Page 2: Safety Rules And Specifications For Mobile Or Manufactured Home Installation

    IMPORTANT! GENERAL SAFETY WARNING WARNING PRECAUTIONS. READ AND UNDERSTAND THESE SAFETY Use care when selecting window Always ensure that the air inlet to RULES BEFORE YOUR FIRST FIRE. treatments for windows located the fireplace is free from debris near the fireplace. Avoid using and any other obstructions that combustible flowing window can block the entrance of air.
  • Page 3: Table Of Contents

    (required if using AC chimney) • Installing The Finishing Kits ....Page 9 The Brentwood LV fireplace is not intended for - AC chimney outside air kit Framing, Facing And Mantel ....Page 10 use with a gas log set. Do not use a fireplace - Gravity venting system Hearth Extension Requirements ..Page 10...
  • Page 4: Operating The Fireplace

    Primary Air and Air Boost Controls Fuel This will help cure the refractory bricks. During There is no flue damper in the Brentwood LV the first few fires of this appliance there may fireplace. As is common with air tight stoves, be some odor and smoke due to the curing of USE SOLID NATURAL WOOD FUEL ONLY.
  • Page 5: Refueling For Best Performance

    Your in this manner. Small dry pieces of softwood dealer can help you determine if you have The Brentwood LV fireplace will operate best if and construction scraps will burn very intensely properly seasoned wood for burning.
  • Page 6: Maintaining Your Brentwood™ Lv Fireplace

    MAINTAINING YOUR BRENTWOOD™ LV Top Baffle Removal Prior to Cleaning The Dealing With a Chimney Fire FIREPLACE Chimney Regular chimney maintenance and inspection Before starting to clean your chimney, we can prevent chimney fires. If you have a chimney Creosote - Formation and Need for Removal recommend that you remove the top baffle to fire, follow these steps: When wood is burned slowly, it produces tar...
  • Page 7: Refractory Installation

    REFRACTORY REPLACEMENT The intense heat of the fire will normally cause hairline cracks in the refractory. These cracks can be minimized by proper curing as described in “First Fires”. They will not normally dimin- ish the effectiveness of the refractory. If large cracks develop, then the refractory should be replaced.
  • Page 8: Glass Care - Replacement

    DO NOT OPERATE THE UNIT WITH CRACKED if additional support is needed. dealer in the following dimensions: OR BROKEN GLASS. The Brentwood LV fireplace may be installed Glass Cleaning directly on the floor or on a raised base (for The Brentwood LV fireplace is designed to...
  • Page 9: Installing The Finishing Kits

    INSTALLING THE FINISHING KITS The gravity kit MUST BE used with the trim and the right side frame. This can be difficult because these are close together to clean face kit to allow hot air flow that allow a good look when using the louver kit. would normally come out of the top louver.
  • Page 10: Framing, Facing And Mantel

    Cover the insulation with Drywall panels around the fireplace. Hearth Extension Requirements 12” Max. The Brentwood LV fireplace may be installed (305mm) directly on a combustible floor. The supplied Mantel safety metal strip must be positioned as follows:...
  • Page 11: Fireplace And Framing Dimensions

    Corner Installation Back Wall of Chase/Enclosure Combustion OUTSIDE CHASE Including Finising Materials if any Air Kit 21-1/2” 20-3/8” Rough Framing Face (Unfinished Shown) * Zero Clearance From Back Spacer to Wall FRAMING DIMENSIONS 36-1/4” 921 mm Combustible materials can NOT be used in the space 2”...
  • Page 12: Insulated Chase Construction

    Insulate Joists Insulated Chase Construction Same As Ceiling Storm Collar Roof Support Flashing Draft Stops Attic Radiation Shield Floor Ceiling Firestop NOTE: It is recommended that the chase Wall walls and floor be insulated in the same CTDT manner, using the same insulation, as Termination the rest of the building, below the attic.
  • Page 13: Facing / Mantel

    Facing Non-Combustible Facing Fireplace Frame Section (Top View) The facing installation method depends on your Drywall finishing kit choice. 2” X 3” Min. 1. Facing with the louver kit - The 2x3 framing (51mm x 76mm) must offset to the back by a distance equiva- Spacer lent to the thickness of your facing material Rockboard...
  • Page 14: Hot Air Ducting Installation

    Maximum length See Figures 20 and 21 * The height of the louver must be measured 45” Min. from the base of the Brentwood LV fireplace to (1143mm) the middle point of the louver. To extend the double outlet system forward...
  • Page 15: Central Forced Air Kit

    CENTRAL FORCED AIR KIT (NOT TESTED The duct system must be installed respecting D) Route the flexible pipe to the chosen location. the following: The ducting system can be installed either UNDER EPA CERTIFICATION) in an upper room or in a lower room. E) Attach the flexible pipe to the fan, using the The knock-outs provided on the back and on 1.
  • Page 16: Outside Air Kit

    OUTSIDE AIR KIT - REQUIRED (Included w/fireplace) OUTSIDE CONNECTION During operation, the fireplace requires fresh air for combustion and draws air out of the house. It may starve other fuel burning appliances such as gas or oil furnaces. As well, exhaust blowers may compete for Aluminum Tape air, causing negative pressure in the house, resulting in smoke entering Outside...
  • Page 17: Chimney System

    AC chimney enclosed in an insulated chase. 9. Cut and frame square holes in all floors, ceilings, and roof that the 2. The fireplace model Brentwood LV may be installed only with Security chimney will go through to provide a 2” (50 mm) clearance between Chimneys International Ltd 6”...
  • Page 18: Chimney Installation Instructions

    CHIMNEY INSTALLATION INSTRUC- Attic Radiation Shield TIONS Attic Radiation ASHT / S2100 Shield HT6103+ / HT6000+ 1. Cut and frame the holes in the ceiling, floor Solid Packed Pipe * Flashing and roof where the chimney will pass (see Figure 28). Use a plumb-bob to line up the center of the holes.
  • Page 19: Offset Chimney Installation

    If penetrating a wall, use Minimum Chimney Height Using Elbows a wall radiation shield. Fireplace Model Brentwood LV 3. Use another elbow to turn the chimney Chimney Model ASHT / S2100+ / HT6103+ / HT6000+ / AC vertically. Lock it to the chimney. Fasten...
  • Page 20 Offset Dimensions Total Height Horizontal Offset Chimney Elbow Offset & One Length Between Elbows Two Lengths Between Elbows 6” Height 8” 12” 18” 24” 36” 48” 8” & 48” 12” & 48” 18” & 48” 24” & 48” 36” & 48” 48”...
  • Page 21: Angled Wall Radiation Shield

    ANGLED WALL RADIATION SHIELD (RSM+ and RSMI30) When traversing a combustible wall with the chimney at a 30º or 45º angle, an angled firestop or wall radiation shield must be installed. Only one is required. Support NOTE: 45º angle for Canada only ( RSMI45 ACRS In cold climate locations (climates where temperatures will fall below 32°...
  • Page 22: Chimney Support Installation

    CHIMNEY SUPPORT INSTALLATION Universal Roof Support 18” (460 mm) 18” (460 mm) When installing a support, slightly lift the chimney system so the weight will lie on the support, not on the fireplace to reduce expansion noises. This support has three possible uses: 1.
  • Page 23: Masonry Application Instructions

    INSTALLATION INSTRUCTIONS FOR MASONRY APPLICATION Follow these steps: 1. Position the fireplace in its location. Temporarily install the ASHT WARNING: Before starting the installation, the masonry chimney elbow on the top of the fireplace and, using a level, mark with an oval must be inspected by a qualified chimney sweep.
  • Page 24: Installation Accessories

    OPTIONAL INSTALLATION ACCESSORIES Installation Accessories Fireplace Kits Description Cat./Part No. Description Cat./Part No. Blower motor speed control (wall mount), VRUW VRUW Finishing Kits (Required - Order Separately) Rigid Firescreen BUCFZN Louver kit LOUVRECF Central Forced Air Kit Accessories Central Forced Air Kit, Central forced air kit including: blower BISFWK-1 Clean face kit CAPPINGCF...
  • Page 25: Replacement Parts

    REPLACEMENT PARTS - BRENTWOOD™ LV SPECIFICATIONS Brentwood™ LV Cat. No. Model H8295 Brentwood™ LV Item # Description Cat./Part No. Baffle refractory (2 pieces) PR-ISO2205 Product Reference Information Back refractory PR-SR2996 Right side refractory PR-SR2997D Weight 385 lbs Left side refractory PR-SR2997G Height 36”...
  • Page 26 REPLACEMENT PARTS - BRENTWOOD™ LV NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
  • Page 27: Chimney Components Lists

    SECURITY CHIMNEYS™ - PARTS AND COMPONENTS LISTS The components listed below must be ordered from Security Chimneys International™. Contact your Security Chimneys Distributor or Dealer for ordering information. Security Chimneys International Limited 450-973-9999 2125 Monterey, Laval, Quebec 1-800-361-4909 (USA) Canada, H7L 3T6 1-800-667-3387 (Canada) www.securitychimneys.com Fireplace Model Brentwood™...
  • Page 28 SECURITY CHIMNEYS™ - PARTS AND COMPONENTS LISTS The components listed below must be ordered from Security Chimneys International™. Contact your Security Chimneys Distributor or Dealer for ordering information. Security Chimneys International Limited 450-973-9999 2125 Monterey, Laval, Quebec Tubinox™ LL Chimney Lining System 1-800-361-4909 (USA) Canada, H7L 3T6 1-800-667-3387 (Canada)
  • Page 29 NOTES...
  • Page 30: Product Reference Information

    WARRANTY Normally, all parts should be ordered through your IHP distributor or dealer. Parts will be shipped at prevailing prices at time of order. Your fireplace is covered by a limited warranty. Please read the warranty When ordering repair parts, always give the following information: to be familiar with its coverage.

Table of Contents