Lennox Hearth Products Brentwood SP Installation & Operation Manual
Lennox Hearth Products Brentwood SP Installation & Operation Manual

Lennox Hearth Products Brentwood SP Installation & Operation Manual

Epa wood-burning fireplaces

Advertisement

Quick Links

SAVE THESE INSTRUCTIONS
FOR FUTURE REFERENCE
• Hot! Do not touch! The glass and
surfaces of this appliance will be hot
during operation and will retain heat
for a while after shutting off the appli-
ance. Severe burns may result.
• Carefully supervise children in the
same room as appliance.
• If small children are present in the home, it
is recommended that this appliance be fitted
with a firescreen kit. See Page 21 for ordering
information.
WARNINGS
Listed to standards:
ULC-S610 & UL-127
Report No. 3011202
EPA Cert. No. 537
PIBRENTW REV. 11 NOV 2008
INSTALLATION AND

OPERATION INSTRUCTIONS

BRENTWOOD™
EPA Wood-Burning Fireplaces
P/N 850,039M REV. G 11/2008
MODEL
BRENTWOOD SP
This installation manual will enable you to obtain a safe, efficient and
dependable installation of your fireplace system. Please read and
understand these instructions before beginning your installation.
Do not alter or modify the fireplace or its components under any circum-
stances. Any modification or alteration of the fireplace system, including
but not limited to the fireplace, chimney components and accessories,
may void the warranty, listings and approvals of this system and could
result in an unsafe and potentially dangerous installation.
Lennox Hearth Products wood-burning fireplaces are designed for use
as a supplemental heater. They are not intended for continuous use
as a primary heat source.
Fireplace, also for use in mobile or
manufactured homes with solid fuel only.
WARNINGS
• The fireplace cannot be operated without a door.
Consult your dealer to select the correct door
model.
• Important! To assure proper alignment of glass
doors: Install this fireplace in a square and
plumb condition, using shims as necessary at
sides and/or bottom.
• Install the fireplace only as described in these
instructions.
TM

Advertisement

Table of Contents
loading

Summary of Contents for Lennox Hearth Products Brentwood SP

  • Page 1: Operation Instructions

    Lennox Hearth Products wood-burning fireplaces are designed for use as a supplemental heater. They are not intended for continuous use as a primary heat source.
  • Page 2: Safety Rules And Specifications For Mobile Or Manufactured Home Installation

    IMPORTANT! GENERAL SAFETY PRECAUTIONS. READ AND UNDERSTAND THESE SAFETY RULES BEFORE YOUR FIRST FIRE. WARNING THE FIREPLACE MUST BE OPER- ATED WITH THE DOOR FULLY OPENED OR DOOR FULLY CLOSED. IF THE DOORS ARE LEFT PARTLY OPENED, GAS AND FLAME MAY BE DRAWN OUT OF THE FIREPLACE OPENING, CREATING RISKS OF BOTH FIRE AND SMOKE.
  • Page 3: Table Of Contents

    CONGRATULATIONS! In selecting this Lennox Hearth Products wood-burning appliance you have chosen one of the finest fireplaces available. The Brentwood™ fireplace is a clean burning EPA certified fireplace that is designed to provide you dependable service as well as warmth and enjoyment for many years to come.
  • Page 4: Combustion Control

    Building a Fire (starting and maintaining a fire) To start a fire, place several crumpled up balls of newspaper in the firebox. Place small dry pieces of kindling on top of the paper, criss-crossing the kindling so that there are air spaces in be- tween.
  • Page 5: Important Cautions

    B. Blowers operating (e.g.: range hood) These blowers draw air out of the house and may actually cause a negative pressure in the house. Turn off all blowers and open a nearby window to determine if this is the cause of the problem. C.
  • Page 6: Refractory Installation

    6. Front Ceramic Baffle 7. Rear Ceramic Baffle Figure 3 • Use only a Lennox Hearth Products glass doors, specifically designed for the Brentwood fireplace. • The fireplace cannot be operated without a door. Consult your dealer to select the correct door model.
  • Page 7: Glass Care - Replacement

    500° F [260° C] is suitable) or adhesion problems may result. Apply gasket cement to the gasket channel and install the new gasket. This replacement part is available from your Lennox Hearth Products dealer in the following dimensions: Gasket Length Dimensions Part No.
  • Page 8: Framing, Facing And Mantel

    Framing, Facing And Mantel The construction of the framing, facing, and mantel must be in accordance with the stan- dards and the following illustrations (Figures 7a, 7b and 8): A. Frame the fireplace using 2” x 3” or heavier lumber. B.
  • Page 9: Fireplace And Framing Dimensions

    Corner Installation 19-3/32” 20-1/2” Min. Fireplace Framing Notes Due to Lennox Hearth Products ongoing commitment to quality, all specifications, ratings and dimensions are subject to change without notice. 1" All framing dimensions calculated for 1/2" dry wall at the fireplace face. If...
  • Page 10 Insulated Chase Construction Attic Radiation Shield Note: Floor and wall below the attic must be insulated using the same insulation. 6’ 8” (2 m) Min. 7’ (2.1 m) Min. Figure 9 1/2” Plywood Facing 1. Combustible material must be installed flush with the fireplace.
  • Page 11: Hot Air Ducting Installation

    HOT AIR DUCTING INSTALLATION The Brentwood™ fireplace is approved for use with a Gravity Kit. Gravity Kit The gravity kit is designed for double hot air out- lets and includes: (See Figures 12 and 13) - 2 telescopic lengths 8” I.D. - 2 90º...
  • Page 12 WARNING: The outlet grills should not be installed fac- ing upward through a floor. Danger of burns can result if grills in floor are stepped Outlet Grill Maintain at least 6-1/2” (160 mm) clearance from the outlet grill framing to a combustible ceiling, side wall or mantel.
  • Page 13: Outside Air Kit

    A furnace duct is only single wall and not double wall as is required for the Brentwood™ fireplace hot air exhaust. 7. Use only Lennox Hearth Products grills and components as described in this manual. Other grills or registers, for example, may be too restrictive and may overheat the fireplace or ceiling.
  • Page 14: Chimney System

    If interior installation is impossible, install an AC chimney enclosed in an insulated chase. 2. The fireplace model Brentwood SP may be installed only with Security Chimneys International Ltd 6” diameter chimney systems. 3. A chimney venting a fireplace shall not vent any other appliance.
  • Page 15: Chimney Installation Instructions

    CHIMNEY INSTALLATION INSTRUC- TIONS 1. Cut and frame the holes in the ceiling, floor and roof where the chimney will pass (see Figure 18). Use a plumb-bob to line up the center of the holes. The sizes are indicated in Table 2 for the floor and ceiling holes and Table 3 (Page 13) for the roof holes.
  • Page 16: Offset Chimney Installation

    18 1/4” (465 mm) 18-3/8” (467 mm) 19 5/8” (500 mm) 20” (508 mm) 21 3/8” (545 mm) Brentwood SP ASHT / S2100+ / HT6103+ / HT6000+ / AC 12 feet (3.66 m) 15 feet (4.57 m) 17 feet (5.18 m) NOTE: DIAGRAMS &...
  • Page 17 Chimney Elbow Offset & One Length Between Elbows 6” Height 8” 12” 15º 3-5/16” 4-5/16” (84mm) (110mm) 15-11/16” 19-9/16” (398mm) (497mm) Secure Temp 30º 7-7/16” 9-7/16” ASHT (189mm) (240mm) Nova 20” 23-1/2” Temp HT6103+ (508mm) (597mm) 45º 10-5/16” 13-3/16” (262mm) (335mm) 17-13/16”...
  • Page 18: Angled Wall Radiation Shield

    Support Straps Note: This illustration is not to scale. It represents how the chimney must be supported. A 30 degree offset only is allowed in the USA and a 45 degree maximum offset is allowed in Canada. Figure 25 - Offset Chimney Installation Rain Cap Framing 2”...
  • Page 19: Chimney Support Installation

    CHIMNEY SUPPORT INSTALLATION Universal Roof Support This support has three possible uses: 1. For ASHT / HT6103+ and S-2100+ / HT6000+, it must be used on a roof to support the chimney. 2. It may be used on a floor, ceiling or roof above an offset to support the chimney above the offset.
  • Page 20: Masonry Application Instructions

    INSTALLATION INSTRUCTIONS FOR MASONRY APPLICATION WARNING: Before starting the installation, the masonry chimney must be inspected by a qualified sweep. The following requirements must be respected: 1. The chimney must be absolutely clear of any soot residue or creosote. Check for cracks, loose or missing bricks that could inhibit correct installation of the liner.
  • Page 21: Installation Accessories

    Rigid firescreen Masonry Chimney Adaptor, 30º, BISUMA30 (for use with TUBINOX liner) Fireplace Model Brentwood SP - Approved Venting Components manu- factured by Security Chimneys International only. • 6” diameter chimney - AC (air cooled), Secure Temp™ ASHT (or Nova Temp™ HT6103+) and Secure Temp S-2100+ (or Nova Temp HT6000+).
  • Page 22 CHIMNEY - PARTS AND COMPONENTS LISTS (AC) Air-Cooled Chimney System* 6” I.D. and 11” O.D. Air Cooled, Stainl. Steel inner and zinc coated steel exterior AC Starter Adaptors One of the following adaptors is required if installing an AC chimney system * AC Chimney is NOT recommended at elevations above 4,000 feet or in cold climates (climates where temperatures will fall below 32°...
  • Page 23: Replacement Parts

    Top: Do not fill the space above the fireplace with any material POIGNE002 (Except the wood framing. See Page 9, Figure 8). Chimney: 2” (50 mm) Mantel: 45” (1143 mm) measured from the base of the fireplace. Model Brentwood SP 385 lbs 36” 36” 24-1/2” 22” x 11-3/4” x 12”...
  • Page 24: Product Reference Information

    Your Dealer's Name _________________________________________________ Your Dealer's Phone Number __________________________________________ Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information.