Message: MPT firmware fault
Description: The adapter did not initialize properly. There may be a
problem with the adapter configuration. Reload the BIOS configuration.
Start the Configuration Utility again and see if the issue persists.
Message: Updating Adapter List!
Description: A new adapter for which there is no record is found. A record
is created for it.
Message: Adapter(s) disabled by user
Description: An adapter is found, but it is disabled in the Configuration
Utility and will not be used by the BIOS.
Message: Adapter configuration may have changed,
reconfiguration is suggested!
Description: A controller is moved or reinstalled in the system. Add it to
the boot order using the available resources.
Message: Memory allocation failed
Description: The controller cannot allocate enough memory to load the
Configuration Utility, its strings file, or its options file. Reboot the system.
Message: Invalid or corrupt image
Description: One of the images for the Configuration Utility, its strings
file, or its options file is corrupt. Reload the BIOS. Reflash the firmware.
Message: Image upload failed
Description: Cannot upload the image for the Configuration Utility, its
strings file, or its options file. Reload the BIOS. Reflash the firmware.
Message: Unable to load the Dell 6 Gbp SAS HBA
Configuration Utility
Description: Cannot load the Configuration Utility. This error usually
follows one of the four previous messages.
Message: Dell 6 Gbp SAS HBA configuration utility
will load after initialization!
Description: <Ctrl><C> is used to start the configuration utility but
insufficient memory is available. The Configuration Utility loads (boots)
after POST initialization.