A-21
Steam
st
□ 1
parameter can be: OFF, ON, PULSE.
○ If OFF, steam remains off for duration of step.
○ If ON, steam remains on for duration of step.
○ If PULSE, pulsed steam is enabled for duration of step.
□ Default is OFF for all steps / programs (no steam).
Pulse-Steam
□ Steam parameter (see above) must be set to PULSE.
□ Pressing Pulse-Steam allows programming TON 0.02 seconds by default.
□ Pressing Pulse-Steam a 2
□ Default is OFF for all steps / programs (no steam).
Fan
st
□ 1
parameter can be: OFF, ON, PULSE.
○ If OFF, fan remains off for duration of step.
○ If ON, fan remains on for duration of step.
○ If PULSE, pulse fan is enabled (pulse mode for duration of step).
■ Pressing Fan a 2
■ Pressing Fan a 3
□ Default is PULSE for all steps/programs.
Rack
(Functional only with oven models with rotating racks).
□ Rack must be enabled in low-level programming to be useable.
□ This can be ON or OFF for each step.
□ Default is ON for all steps / programs, if enabled in low-level programming.
Step End
□ Step End defines what happens with the end of a Cook Program Step (Stop key is used to
program Step End parameter).
○ AUTO: nothing happens, automatically move on to the next step (buzzer output remains
off).
○ WARN: move on automatically to the next step, but turn on buzzer output for 5 seconds.
○ MANUAL: activates buzzer output until user manually presses Start key to enable next
step.
○ LAST: activate buzzer output until user manually presses Stop key to end the recipe.
□ Default is AUTO for all steps / programs.
Food Probe in Programming Mode
□ Food temperature can be programmed to the following settings OFF ON MONITOR.
○ ON: using food temperature's programming set point to end the current step at that
temperature.
○ OFF: default for all steps / programs.
○ MONITOR: to ignore food probe temperature, but still display the information if
requested.
nd
time allows programming TOFF 0.30 seconds by default.
nd
time allows programming TON 02.30 minutes by default.
rd
time allows programming TOFF from 0.25 seconds by default.