Technical Specifications - HP ProLiant ML310e Specification

Hp proliant ml310e generation 8 (gen8) v2
Hide thumbs Also See for ProLiant ML310e:
Table of Contents

Advertisement

QuickSpecs

Technical Specifications

System Unit
Tower Dimensions
(H x W x D)
(with feet/bezel)
Tower Weight
(approximate)
Input Requirements
(per power supply)
BTU Rating
Power Supply Output
(per power supply)
System Inlet
Temperature
Relative Humidity
(non-condensing)
Altitude
Acoustic Noise
DA - 14564 Worldwide — Version 11 — December 13, 2013
HP ProLiant ML310e Generation 8 (Gen8) v2
14.5.x 6.89 x 18.71 in (36.82 x17.5 x 47.52 cm)
Maximum
(all hard drives, power
supplies, and processors
installed)
Minimum
(one hard drive, power
supply, and processor
installed)
Rated Line Voltage
Rated Input Current
Rated Input Frequency
Rated Input Power
Maximum
Rated Steady-State Power 350 W (at 100 VAC),
Maximum Peak Power
Operating
Non-operating
Operating
Non-operating
Operating
Non-operating
Listed are the declared A-Weighted sound power levels (LWAd) and declared
41.8 lb (18.96 kg)
25.29 lb (11.47 kg)
100 to 240 VAC
6 Amps
47 to 63 Hz
440W at 100 V AC input
440W at 200V AC input
460W - 1773 BTU / hr (at 120 VAC), 1715 (at 240
VAC)
350 W (at 200 VAC)
350 W (at 100 VAC),
350 W (at 200 VAC)
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 304.8 m (1.8°F
per every 1000 ft) above sea level to a maximum
of 3048 m (10,000 ft), no direct sustained
sunlight. Maximum rate of change is 10°C/hr
(18°F/hr). The upper limit may be limited by the
type and number of options installed.
System performance may be reduced if operating
with a fan fault or above 30°C (86°F).
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
10 to 90% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-
condensing.
5 to 95% relative humidity (Rh), 38.7°C (101.7°F)
maximum wet bulb temperature, non-
condensing.
3048 m (10,000 ft). This value may be limited by
the type and number of options installed.
Maximum allowable altitude change rate is 457
m/min (1500 ft/min).
9144 m (30,000 ft). Maximum allowable altitude
change rate is 457 m/min (1500 ft/min).
Page 40

Advertisement

Table of Contents
loading

This manual is also suitable for:

Proliant ml310e generation 8Proliant ml310e g8 v2

Table of Contents