Accessories/Replacement Parts; Specifications - Honeywell FocusPRO TH5220D Installation Manual

Non-programmable digital thermostat
Hide thumbs Also See for FocusPRO TH5220D:
Table of Contents

Advertisement

FocusPRO
TH5220D Non-programmable Digital Thermostat
In case of difficulty
Heating equip-
ment is running
in cool mode
Cannot change
system setting
to "Heat"
Cannot change
system setting
to "Cool"
"Heat On" is
not displayed
"Cool On" is not
displayed
"Cool On" or
"Heat On"
is flashing
Accessories & replacement parts
Please contact your distributor to order replacement parts.
Battery holder ......................................................Part Number 50007072-001
Cover plate assembly ........................................Part Number 50002883-001
(Use to cover marks left by old thermostats.)

Specifications

Temperature Ranges
• Heat: 40° to 90°F (4.5° to 32°C)
• Cool: 50° to 99°F (10° to 37°C)
Operating Ambient Temperature
• 32° to 120°F (0° to 48.9°C)
Shipping Temperature
• -20° to 120°F (-28.9° to 48.9°C)
Operating Relative Humidity
• 5% to 90% (non-condensing)
Physical Dimensions
• 3-9/16" H x 5-13/16" W x 1-1/2" D
• 91 mm H x 147 mm W x 38 mm D
• Check Installer Setup, Function 1 (System Type), to make sure it is set to
match the installed heating/cooling equipment (see page 11).
• Check Installer Setup, Function 1 (System Type), to make sure it is set to
match the installed heating equipment (see page 11).
• Change Installer Setup, Function 12 (System Setting) to Manual or Auto
Changeover (see page 12).
• Check Installer Setup, Function 1 (System Type), to make sure it is set to
match the installed cooling equipment (see page 11).
• Change Installer Setup, Function 12 (System Setting) to Manual or Auto
Changeover (see page 12).
• Change the System Setting to Heat, and set the temperature level above
the current room temperature.
• Change the System Setting to Cool, and set the temperature level below
the current room temperature.
• Compressor protection timeout is engaged. Wait 5 minutes for the
system to restart safely, without damage to the compressor.
Electrical Ratings
Terminal
Voltage (50/60Hz) Running Current
W (O/B) Heating
(Powerpile)
W2 (Aux) Heating
Y Cooling
Y2 Cooling
G Fan
E Emergency heat
L Heat pump reset
17
20-30 Vac
0.02-1.0 A
750 mV DC
100 mA DC
20-30 Vac
0.02-0.5 A
20-30 Vac
0.02-1.0 A
20-30 Vac
0.02-1.0 A
20-30 Vac
0.02-0.5 A
20-30 Vac
0.02-1.0 A
20-30 Vac
0.02-0.5 A