Extreme Networks Summit X250e Series Technical Specifications page 11

Edge power over ethernet (poe) and non-poe switch providing intelligent 10/100base-t connectivity
Hide thumbs Also See for Summit X250e Series:
Table of Contents

Advertisement

Extreme Networks Data Sheet: Summit X250e Series
Summit X250e-24xDC
General Specifications
Performance
48.8 Gbps switch fabric bandwidth
36.3 Mpps frame forwarding rate
9,216 Byte maximum packet size (Jumbo Frame)
128 load sharing trunks, up to 8 members per trunk
8 QoS queues/port
4,094 VLANs (Port, Protocol, IEEE 802.1Q)
1,024 centralized ACL rules per switch
Forwarding Tables
Layer 2/MAC Addresses: 8K
IPv4 LPM Entries: 512
IPv6 LPM Entries: 256
Rate Limiting
Ingress bandwidth policing/rate limiting per flow
Egress bandwidth rate shaping per egress queue and per port
Rate Limiting Granularity: 64Kbps
Available Rate Limiters: 1,024 per switch
Indicators
Per port status LED
System Status LEDs: management, fan and power
Ports
24 ports 100BASE-X supporting 100BASE-X SFP Optical Transceivers
2 ports Gigabit Ethernet (100/1000BASE-X SFP, shared PHY with 2
10/100/1000BASE-T ports)
2 SummitStack stacking interfaces
1 port Serial (control port)
1 10/100BASE-T out-of-band management port
External Power Supply Support
EPS-150DC with EPS-T2
Physical Specifications
Dimensions and Weight
Height: 1.73 Inches/4.4 Cm
Width: 17.35 Inches/44.1 Cm
Depth: 12.13 Inches/30.8 Cm
Weight: 9.97 Lbs/ 4.53 Kg
Operating Specifications
Power & Acoustic Sound
Voltage Input Range: -40 to -72VDC
Input Current Rating: 2.0A at -48VDC
Input Current: 1.25A @ -40VDC, 0.75A @ -72VDC
Maximum In-Rush Current: 20A@-48VDC, 30A@-72VDC
Efficiency: 83%
Power Supply Input Socket: TYCO 206061-1
Power Cord Input Plug: TYCO 206060-1
Heat Dissipation: 42W (143.3 BTU/h)
Power Consumption: 47W (160.4 BTU/h)
Acoustic Noise (Low FAN Speed): 37 dBA per ISO 7779
Acoustic Noise (High FAN Speed): 47 dBA per ISO 7779
Summit X250e Series
Regulatory/Safety Standards
North American Safety of ITE
UL 60950-1 1st Ed., Listed Device (U.S.)
CSA 22.2#60950-1-03 1st Ed. (Canada)
Complies with FCC 21CFR 1040.10 (U.S. Laser Safety)
CDRH Letter of Approval (U.S. FDA Approval)
European Safety of ITE
EN60950-1:2001+A11
EN 60825-1+A2:2001 (Lasers Safety)
TUV-R GS Mark by German Notified Body
2006/95/EC Low Voltage Directive
International Safety of ITE
CB Report & Certificate per IEC 60950-1:2001 + National Differences
AS/NZS 60950-1 (Australia/New Zealand)
EMI/EMC Standards
North America EMC for ITE
FCC CFR 47 part 15 Class A (U.S.)
ICES-003 Class A (Canada)
European EMC Standards
EN 55022:2003 Class A
EN 55024:A2-2003 Class A includes IEC 61000-4-2, 3, 4, 5, 6, 11
EN 61000-3-2,2006 (Harmonics)
EN 61000-3-3 1995+A1:2001 (Flicker)
ETSI EN 300 386 v1.3.3, 2005-04 (EMC Telecommunications)
2004/108/EC EMC Directive
International EMC Certifications
CISPR 22: 2005, Class A (International Emissions)
CISPR 24:A2:2003 Class A (International Immunity)
IEC/EN 61000-4-2:2001 Electrostatic Discharge, 8kV Contact, 15 kV Air,
Criteria A
EC/EN 61000-4-3:2002 Radiated Immunity 10V/m, Criteria A
EC/EN 61000-4-4:2004 Transient Burst, 1 kV, Criteria A
IEC/EN 61000-4-5:2001 Surge, 2 kV L-L, 2 kV L-G, Level 3, Criteria A
IEC/EN 61000-4-6:2004 Conducted Immunity, 0.15-80 MHz, 10V/m
unmod. RMS, Criteria A
EC/EN 61000-4-11:2004 Power Dips & Interruptions, >30%, 25 periods,
Criteria C
Country Specific
VCCI Class A (Japan Emissions)
ACMA (C-Tick) (Australia Emissions)
KCC Mark EMC Approval (Korea)
Telecom Standards
EN/ETSI 300 386:2001 (EMC Telecommunications)
EN/ETSI 300 019 (Environmental for Telecommunications)
MEF9 and MEF14 certified for EPL, EVPL and ELAN
NEBS Level 3 compliant to portions of GR-1089 Issue 4 & GR-63 Issue
3 as defined in SR3580 with exception to filter requirement
IEEE 802.3 Media Access Standards
IEEE 802.3 10BASE-T
IEEE 802.3u 100BASE-TX
IEEE 802.3ab 1000BASE-T
IEEE 802.3z 1000BASE-X
Technical Specifications
11

Advertisement

Table of Contents
loading