Factory-Default Settings for Security Policies:
Source Zone
Destination Zone
trust
untrust
trust
trust
untrust
trust
Factory-Default Settings for NAT Rules:
Source Zone
Destination Zone
trust
untrust
NOTE: Source NAT translates the source address for packets coming from any number
of hosts on a private network to one public IP address.
Task 1: Connect the Power Cable to the Device
Connect the power supply adapter to the power supply point on the device and to a
power source. We recommend using a surge protector. Secure the connector to the
power supply point by wrapping a cable tie around the cable boot and the adjacent cable
tie holder. Note the following indications:
POWER LED (green): The device is receiving power.
STATUS LED (green): The device is operating normally.
ALARM LED (amber): The device is operating normally, but the LED might glow
amber if a rescue configuration has not been set. This is not a panic condition.
mPIM LED (off): The Mini-Physical Interface Module (Mini-PIM) is not present or is
not detected by the device. If this LED is solid green, it indicates that the Mini-PIM is
functioning normally.
NOTE: After a rescue configuration has been set, an amber ALARM LED indicates a
minor alarm, and a solid red ALARM LED indicates a major problem on the services
gateway.
NOTE: You must allow the device between five and seven minutes to boot after you
power it on. Wait until the STATUS LED is solid green before proceeding to the next
task.
Task 2: Connect the Management Device
Connect the management device to the services gateway, using either of the following
methods:
Connect an RJ-45 cable (Ethernet cable) from one of the following ports on the front
panel to the Ethernet port on the management device (workstation or laptop):
0/1 (interface ge-0/0/1)
0/2 through 0/7 (interfaces fe-0/0/2 through fe-0/0/7)
We recommend this connection method. If you are using this method to connect,
proceed to Task 3.
Policy Action
permit
permit
deny
See the following illustration for details about connecting the management interface by
using the Ethernet ports.
Policy Action
source NAT to untrust zone
interface
Task 3: Ensure That the Management Device Acquires an IP Address
After you connect the management device to the services gateway, the DHCP server
process on the services gateway automatically assigns an IP address to the
management device. Ensure that the management device acquires an IP address on the
192.168.1.0/24 subnetwork (other than 192.168.1.1) from the services gateway.
NOTE:
Task 4: Access the J-Web Interface
1.
2.
Connect an RJ-45 cable (Ethernet cable) from the port labeled CONSOLE to the
supplied DB-9 adapter, which then connects to the serial port on the management
device (serial port settings: 9600 8-N-1).
If you are using this method to connect, proceed with the CLI configuration
instructions in the Branch SRX Series Services Gateways Golden Configurations at
http://www.juniper.net/us/en/local/pdf/app-notes/3500153-en.pdf.
The services gateway functions as a DHCP server and will assign an IP address to
the management device.
If an IP address is not assigned to the management device, manually configure an
IP address in the 192.168.1.0/24 subnetwork. Do not assign the 192.168.1.1 IP
address to the management device because this IP address is assigned to the
services gateway. By default, the DHCP server is enabled on the L3 VLAN interface,
(IRB) vlan.0 (ge-0/0/1 and fe-0/0/2 to fe-0/0/7), which is configured with an IP
address of 192.168.1.1/24.
When an SRX210 Services Gateway is powered on for the first time, it boots using
the factory-default configuration.
Launch a Web browser from the management device.
NOTE: The wizard works best with Mozilla Firefox version 15.x or later.
Type http://192.168.1.1 in the URL address field. The Welcome page appears.