Adapting the boiler to the heating installation
Code
Parameters
D.067
Remaining burner anti-cycling time
D.068
Unsuccessful ignitions at 1st attempt
D.069
Unsuccessful ignitions at 2nd attempt
D.070
Setting diverter valve position
D.071
Target value maximum heating flow tem-
perature
D.072
Internal pump overrun after cylinder
charging
D.073
Warm start target offset
D.075
Max. charging time for domestic hot
water cylinder without independent con-
trol system
D.076
Device specific number
D.077
Limit on cylinder charging output
in kW
D.078
Limit on cylinder charging temperature
in °C
D.080
Operating hours, heating
D.081
Operating hours, hot water generation
D.082
Number of burner start-ups in heating
mode
D.083
Number of burner start-ups in hot water
mode
D.084
Maintenance indicator: Number of hours
until the next maintenance
D.088
Start delay for hot water draw-off detec-
tion via impeller (VUW boilers only)
D.090
Status of digital controller
D.091
Status DCF with external sensor con-
nected
D.092
actoSTOR module recognition
D.093
Invalid device specific number (DSN)
D.094
Delete fault history
D.095
Software version of PeBUS components
D.096
Factory setting
11.1 Diagnosis codes (continued)
46
Adjustable values
In minutes
Number of unsuccessful ignitions
Number of unsuccessful ignitions
0 = Normal mode
1 = Mid-position (parallel mode)
2 = Permanent heating setting
40 to 80 °C
Not relevant
Adjustable from -15 K to 5 K
Not relevant
16 = VU 22
16 = VUW 26
Not relevant
Not relevant
In hours (h)
In hours (h)
Number of burner start-ups
Number of burner start-ups
Setting range: 0 to 3000 hrs and "---" for deactivated
0 = 1.5 l/min and no delay,
1 = 3.7 l/min and 2 sec. delay
1 = Recognised, 0 = Not recognised
0 = No reception, 1 = Reception, 2 = Synchronised, 3 =
Valid
Not relevant
Setting range: 0 to 99
Delete fault list
PCB (BMU)
Display (AI)
Reset all adjustable parameters to default setting
Installation and maintenance instructions ecoTEC 0020173113_01
Factory
Your own
setting
setting
Not adjustable
Not adjustable
Not adjustable
0
75 °C
Not adjustable
0
Not adjustable
Not adjustable
Not adjustable
Not adjustable
Not adjustable
Not adjustable
Not adjustable
Not adjustable
"---"
0
Not adjustable
Not adjustable
Not adjustable