Connection In Applications - Bosch NBN-733 Installation Manual

Dinion hd 720p60
Hide thumbs Also See for NBN-733:
Table of Contents

Advertisement

DINION HD
1.3

Connection in applications

Grounding
Safety (power) ground is indicated by the symbol
rear of the camera.
U.S.A.: - section 810 of the National Electrical Code, ANSI/NFPA
No.70, provides information regarding proper grounding.
12 VDC / 24 VAC power source: This unit is intended to
operate with a limited power source. The unit is intended to
operate at either 12 VDC or 24 VAC (if PoE is not available).
User supplied wiring must be in compliance with electrical
codes (Class 2 power levels).
PoE: Use only approved PoE devices. Power-over-Ethernet can
be connected at the same time as a 12 VDC or 24 VAC power
supply.
If auxiliary power (12 VDC or 24 VAC) and PoE is applied
simultaneously, the camera selects auxiliary input and shuts off
the PoE.
Bosch Security Systems
Installation Manual
Safety | en
on the
AM18-Q0614 | v1.0 | 2012.09
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dinion hd nbn-733

Table of Contents