Cooling Module Specifications; Raid Management - Bosch DVA-16K SCSI Installation Manual

Raid subsystem scsi premium series
Hide thumbs Also See for DVA-16K SCSI:
Table of Contents

Advertisement

62
en | Appendix: Specifications
7.5

Cooling Module Specifications

Max. Air Flow
Input Power
Input Current
Rated Voltage
Acoustic Noise
Temperature
7.6

RAID Management

Configuration
Performance Monitoring
Remote Control and Moni-
toring
Event Broadcast/Alert
Event Notification
Hardware Connection
Configuration on Disk
Failure Indicator
F.01U.027.799 | V2 | 2008.08
RAID Subsystem DVA-16K | Installation Manual
Specifications
High speed: 31.8 CFM
Low speed: 20.1 CFM
9 W max.
0.89A max.
DC 12V
High speed: 55dB max.
Low speed: 44dB max.
Operating: -10 to +60ºC
Storage: -20 to +70ºC
Specifications
Text-based firmware-embedded utility over RS-232C
through the included serial cable
LCD keypad panel
The Bosch RAIDWatch Manager program using in-band
or Ethernet connection
Yes
Yes
Yes, via Java-based Bosch RAIDWatch Manager and Event
Monitor
Yes, via the Bosch RAIDWatch Configuration Client sub-
module
In-band over SCSI/Fiber, out-of-band via Ethernet or
RS232C
Configuration data stored on disks for logical drive assem-
blies to exist after controller replacement.
Faults are indicated via alarm, module LED indicators, LCD
panel, Bosch RAIDWatch Manager, or terminal emulation.
Bosch Security System

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dva-16k series

Table of Contents