Agilent Technologies E1343A Service Manual
Agilent Technologies E1343A Service Manual

Agilent Technologies E1343A Service Manual

75000 series b relay multiplexers
Hide thumbs Also See for E1343A:
Table of Contents

Advertisement

Quick Links

Agilent 75000 Series B
Agilent E1343A, E1344A, E1345A, E1347A,
E1355A and E1356A
Relay Multiplexers
Service Manual
Copyright © Agilent Technologies, Inc. 2005
Printed in Malaysia

Advertisement

Table of Contents
loading

Summary of Contents for Agilent Technologies E1343A

  • Page 1 Agilent 75000 Series B Agilent E1343A, E1344A, E1345A, E1347A, E1355A and E1356A Relay Multiplexers Service Manual Copyright © Agilent Technologies, Inc. 2005 Printed in Malaysia...
  • Page 3: Table Of Contents

    Multiplexer Descriptions ....... . . 15 E1343A/44A Descriptions ....... 15 E1345A/47A Descriptions .
  • Page 4 Service Aids ........49 E1343A/44A Multiplexer Descriptions ......50 E1345A/47A Multiplexer Descriptions .
  • Page 5: Warranty

    Agilent warrants that its software and firmware designated by Agilent for use with a product will execute its programming instructions when properly installed on that product. Agilent does not warrant that the operation of the product, or software, or firmware will be un- interrupted or error free.
  • Page 6: Safety Symbols

    REMOVE POWER and do not use the product until safe operation can be verified by service-trained personnel. If necessary, return the product to an Agilent Technologies Sales and Serv- ice Office for service and repair to ensure that safety features are maintained.
  • Page 7: Declaration Of Conformity

    Declaration of Conformity Declarations of Conformity for this product and for other Agilent products may be downloaded from the Internet. There are two methods to obtain the Declaration of Conformity: • Go to http://regulations.corporate.agilent.com/DoC/search.htm . You can then search by product number to find the latest Declaration of Conformity.
  • Page 8 Notes E1343A/44A/45A/47A/55A/56A Service Manual...
  • Page 11: Manual Overview

    What’s in This Manual Manual Overview This manual shows how to service the E1343A, E1344A, E1345A, E1347A, E1355A, and E1356A Relay Multiplexers. Consult the E1343A/E1344A/E1345A/E1347A User’s Manual for additional information on installing, configuring, and operating the E1343A, E1344A, E1345A and E1347A. Consult the E1355A/E1356A Strain Gage Multiplexer User’s Manual for additional information on installing,...
  • Page 12 Notes 10 What’s In This Manual E1343A/44A/45A/47A/55A/56A Service Manual...
  • Page 13: Chapter 1. General Information

    Figure 1-1 shows a typical layout for each of the relay multiplexers. Each multiplexer consists of a component assembly and a terminal module. The Agilent E1345A, E1347A, E1355A, and E1356A multiplexers use the same component assembly, but each multiplexer uses a unique terminal module.
  • Page 14: Safety Considerations

    Safety Considerations These products are Safety Class I instruments provided with a protective earth terminal when installed in the mainframe. Check the mainframe, multiplexer, and all related documentation for safety markings and instructions before operation or service. Refer to the WARNINGS on page 4 in this manual for a summary of safety information.
  • Page 15: Cautions

    E1347A, E1355A, and E1356A modules. The maximum voltage that may be applied between High (H), Low (L), and Guard (G) terminals is 250VDC or ACrms (354Vpeak) for the E1343A or E1344A. The maximum current is 50 mA (non-conductive) per channel. The maximum power per channel is 1 VA.
  • Page 16: Relay Life

    Relay Life Electromagnetic relays are subject to normal wear-out. Relay life depends on several factors. Two factors are loading and switching frequency effects. Loading and Relay Load. In general, higher power switching reduces relay life. In addition, capacitive/inductive loads and high inrush currents (e.g., when Switching turning on a lamp or motor) reduce relay life.
  • Page 17: Replacement Strategy

    250VDC or VACrms. The E1344A provides Descriptions a thermistor reference junction on the terminal card for thermocouple measurements. Both modules use the E1343A relay component module but they have different terminal card assemblies. E1345A/47A The E1345A and E1347A multiplexers provide multiplexing for up to 16 channels (channels 00 through 15).
  • Page 18: Multiplexer Specifications

    Manual Update (as required) will explain how to adapt this manual to your instrument. Multiplexer Options There are no electrical or mechanical options available for the E1343A, E1344A, E1345A, E1347A, E1355A, E1356A Relay Multiplexers. Schematics and Component locators and schematics for the multiplexers are packaged with this manual.
  • Page 19: Recommended Test Equipment

    Recommended Test Equipment Table 1-1 lists the test equipment recommended for testing, adjusting, and servicing the relay multiplexers. Essential requirements for each piece of test equipment are described in the Requirements column. Table 1-1. Recommended Test Equipment Instrument Requirements Recommended Use* Model Controller, HP-IB...
  • Page 20 Figure 1-2. Initial (Incoming) Inspection Guidelines 18 General Information Chapter 1...
  • Page 21: Shipping Guidelines

    Shipping Guidelines Follow the steps in Figure 1-3 to return a relay multiplexer to an Agilent Technologies Sales and Service Office. 1. Prepare the Multiplexer * Remove user wiring from terminal block * Attach tag to module/pod that identifies - Owner...
  • Page 22 Notes 20 General Information Chapter 1...
  • Page 23: Chapter 2. Verification Tests

    Chapter 2 Verification Tests Introduction This chapter describes the verification tests for the E1343A, E1344A, E1345A, E1347A, E1355A, E1356A Relay Multiplexers. The three levels of test procedures described in this chapter are used to verify that the modules: • are functional (Functional Verification Test) •...
  • Page 24: Functional Verification Test

    Functional Verification Test The Functional Verification Test for the multiplexer modules consists of sending the command and checking the response. This test can be *IDN? used to verify that the multiplexer is connected properly and is responding to a basic command. Procedure 1.
  • Page 25: Performance Verification Tests

    The E1345A terminal module may be used to test the E1343A/45A/55A and 56A. The terminal module part number is E1345-80001. The E1347A terminal module may be used to test the E1344A and 47A.
  • Page 26 DMM (see Figure 2-2). Record the measured values in Table 2-1. NOTE On the E1343A and E1344A, Resistors R22, R25, R28, and R31 are 1.0kΩ resistors. Figure 2-2. Typical Resistance Measurement Connections Table 2-1. Measured Protection Resistor Values...
  • Page 27 Chs 00 - 07 and 90 1. Make Hardware Connections HI Measurements Turn mainframe power OFF – Connect DMM leads as shown in Figure 2-3 – Turn mainframe power ON – Figure 2-3. Ch 0-7 and 90 HI Measurements Connections 2.
  • Page 28 Figure 2-4. Ch 0-7 and 90 LO Measurement Connections 3. Repeat for Channels 01 - 07 LO and Channel 90 LO Repeat steps 1 and 2 for channels 01 - 07 LO and 90 LO – , where CLOS (@nncc) OPEN (@nncc) –...
  • Page 29 3. Repeat for Channels 01 - 07 GU and Channel 90 GU Repeat steps 1 and 2 for channels 01 - 07 GU and 90 GU – , where – CLOS (@nncc) OPEN (@nncc) card # and = channel # (omit leading zeroes in For Channel 90 GU, subtract combined value of R22 + R28 –...
  • Page 30 Figure 2-7. Chs 08-15 and 91-92 LO Measurements Connections 2. Measure Channel 08 LO Resistance Send to multiplexer *RST – Send to close chan 08, where = card # CLOS (@nn08) – Trigger the DMM with and note reading TRIG SGL –...
  • Page 31 2. Measure Channel 08 GU Resistance Send to multiplexer *RST – Send to close chan 08, where = card # – CLOS (@nn08) Trigger the DMM with and note reading TRIG SGL – Send to open channel 08 – OPEN (@nn08) Subtract measured value of R25 from DMM reading –...
  • Page 32 PRINT TABXY(1,5),"Measure resistor R";I;"value (in Ohms)" INPUT " Enter resistor value (in Ohms), then press Continue ",R(I) 220 NEXT I 230 CLEAR SCREEN 240 PRINT "Install Component Assembly and Test Fixture " 250 PRINT 260 PRINT " 1. Turn Mainframe power OFF" 270 PRINT "...
  • Page 33 PRINT "Resistance for Channel";I;"Relay is >2.0 Ohms" PAUSE END IF NEXT I IF K<2 THEN PRINT "Measurements complete for Channels 00 - 07 and 90 ";Path$(K) DISP " Press Continue for Channels 00 - 07 and 90 ";Path$(K+1);" measurements " PAUSE ELSE PRINT "...
  • Page 34 IF I=8 AND K=2 THEN Result1(I,K)=Value1(I,K)-(R(25)+R(31)) 1000 IF I=9 AND K=0 THEN Result1(I,K)=Value1(I,K)-(R(23)+R(26)) 1010 IF I=9 AND K=1 THEN Result1(I,K)=Value1(I,K)-(R(24)+R(27)) 1020 IF I=9 AND K=2 THEN Result1(I,K)=Value1(I,K)-(R(25)+R(28)) 1030 IF Result1(I,K)<0. THEN Result1(I,K)=0. 1040 IF Result1(I,K)>2.0 THEN 1050 PRINT "Resistance for Channel";I;"Relay is >2.0 Ohms" 1060 PAUSE 1070...
  • Page 35 Typical Results Channel HI (OHMS) LO (OHMS) GU (OHMS) 0.51 0.35 0.61 0.31 0.59 0.49 0.48 0.41 0.57 0.42 0.39 0.61 0.52 0.41 0.55 0.52 0.35 0.59 0.49 0.40 0.60 0.46 0.36 0.54 0.49 0.40 0.55 0.47 0.35 0.60 0.51 0.36 0.61 0.55...
  • Page 36 1. Make hardware connections as shown in Figure 2-9 HI to Chassis Isolation 2. Set DMM to 2-wire ohms, 1 GΩ range 3. Send to close all relays CLOS (@nn00:nn15, nn90:nn93) 4. Trigger the DMM with TRIG SGL 5. Record the DMM reading on Table 2-2 (HI to Chassis) Figure 2-9.
  • Page 37 HI to GU Isolation 1. Make hardware connections as shown in Figure 2-11 2. Trigger the DMM with TRIG SGL 3. Record the DMM reading on Table 2-2 (HI to GU) Figure 2-11. HI to GU Isolation Connections This example performs DC Isolation Tests for HI to Chassis, HI to LO, and Example: DC Isolation HI to GU (GUARD).
  • Page 38 160 PAUSE 170 CLEAR SCREEN 180 ! ! Measure DC Isolation (HI to Chassis, HI to LO, HI to GU) 200 ! 210 OUTPUT @Mux;"*RST" 220 FOR I=0 TO 2 PRINT TABXY(1,1),"DC Isolation HI to ";Conn$(I);" Measurements " PRINT TABXY(1,3),"1. Connect DMM INPUT HI lead to COMMON HI"...
  • Page 39: Performance Test Record

    Performance Test Record Table 2-2, "Performance Test Record," is a form you may copy and use to record performance verification test results for the multiplexers. Table 2-2 shows multiplexer test limits, DMM measurement uncertainty, and test accuracy ratio (TAR) values. Test Limits Test limits are defined for relay closed channel resistance and DC isolation using the specifications in the individual module’s User’s Manual.
  • Page 40 Table 2-2. Performance Test Record (Page 1 of 3) General Information Test Facility: Name_______________________________________ Report No._________________________________ Address_____________________________________ Date______________________________________ City/State____________________________________ Customer__________________________________ Phone______________________________________ Tested by__________________________________ Special Notes: ____________________________________________________________________________________________ ____________________________________________________________________________________________ ____________________________________________________________________________________________ ____________________________________________________________________________________________ ____________________________________________________________________________________________ ____________________________________________________________________________________________ Test Equipment Record Model ________________________________ Report No. ___________________ Date __________________ Test Equipment Used: Model No.
  • Page 41 Table 2-2. Performance Test Record (Page 2 of 3) Test No/Description Minimum* Measured Value Maximum Measurement Test Acc Value Value Uncert Ratio (TAR) 2-1. Closed Channel Resistance (Values in Ohms) HI Path Resistance Channel 00 __________________ 8.00E-5 Channel 01 __________________ 8.00E-5 Channel 02 __________________...
  • Page 42 Table 2-2. Performance Test Record (Page 3 of 3) Test Minimum* Measured Value (V) Maximum* Meas Test Acc No/Description Value * Value Uncert Ratio (TAR) 2-1. Closed Channel Resistance (Values in Ohms) (cont’d) GU Path Resistance Channel 00 ___________________ 8.00E-5 Channel 01 ___________________ 8.00E-5...
  • Page 43: Chapter 3. Replaceable Parts

    • Table 3-4 shows reference designators for parts in Tables 3-2 and 3-3. To order a part listed in Tables 3-2 and 3-3, specify the Agilent part number and the quantity required. Send the order to your nearest Agilent Technologies Sales and Service Office.
  • Page 44: Replaceable Parts

    Table 3-1. Relay Multiplexer Assembly/Terminal Module Part Numbers Multiplexer Component Terminal Terminal Terminal Assembly Module Card Case Assy E1343A 16-Channel High-Voltage Relay Mux E1343-66201 E1343-80001 E1345-66510 E1300-84401 E1344A 16-Channel High-Voltage Relay E1343-66201 E1344-80001 E1347-66510 E1300-84401 Mux with TC E1345A 16-Channel Mux...
  • Page 45: Chapter 3 Replaceable Parts

    Table 3-2. E1345A/47A/55A/56A Replaceable Parts (cont’d) Reference Part Part Description Designator Number TERMINAL MODULES E1345-80001 E1345A TERMINAL MODULE (See Figure 3-2) E1345-66510 TERMINAL CARD - 16 CH RLY MUX E1300-84401 CASE - TERMINAL MODULE ASSY E1347-80001 E1347A TERMINAL MODULE (See Figure 3-2) E1347-66510 TERMINAL CARD - 16 CH T/C MUX E1300-84401...
  • Page 46 RBN CBL 6-PIN 20-IN E1326B (INT) TO RLY MUXS E1300-61605 RBN CABLE 6-PIN 2-IN RLY MUXS TO RLY MUXS E1400-61605 RBN CABLE 6-PIN 2.5-IN RLY MUXS TO RLY MUXS COMPONENT ASSY (E1343-66201) (common to both E1343A/44A Relay Muxs) See Figure 3-1 BRK1-BRK2 0050-2183 CASTING-ZN P.C. BOARD HOLDER LBL1...
  • Page 47 Table 3-4. Reference Designators Reference Designators assembly printed circuit board bracket panel capacitor transistor diode resistor case resistor pack fuse thermistor probe electrical connector (jack) screw jumper shield relay switch label terminal module (block) mechanical part integrated circuit electrical connector (plug) Chapter 3 Replaceable Parts 45...
  • Page 48: Parts Locators

    Parts Locators Figures 3-1 through 3-3 show locations of replaceable parts for the E1343A, E1344A, E1345A, E1347A, E1355A, and E1356A Relay Multiplexers with serial numbers that fall within a specific range. (See applicable serial number ranges on the first page of this chapter.) See Table 3-4 for Reference Designators.
  • Page 49 Figure 3-2. E1343A, E1344A, E1345A, E1347A Terminal Module Mechanical Parts Chapter 3 Replaceable Parts 47...
  • Page 50 Figure 3-3. E1355A/E1356A Terminal Module Mechanical Parts 48 Replaceable Parts Chapter 3...
  • Page 51: Chapter 4. Service

    Information," for descriptions and locations of the replaceable parts, depending on the serial number of your multiplexer. Service notes, manual updates, and service literature for the multiplexers may be available through Agilent Technologies. For information, contact your nearest Agilent Technologies Sales and Service Office. Chapter 4...
  • Page 52: E1343A/44A Multiplexer Descriptions

    HIGH (H), LOW (L), and GUARD (G) connections. See Figure 4-1 for a block diagram of these modules. The component assembly is the same for the E1343A and E1344A. The only difference between the two component assemblies is their module ID jumper settings.
  • Page 53: E1345A/47A Multiplexer Descriptions

    Terminal module connections include H, L, and G terminals for Channels 00 - 15, Bank 0 and Bank 1 Commons, and the AT and BT Tree Switches. In addition, each channel H line has a jumper on the terminal module that can be removed to add filter components, attenuators, or current shunts.
  • Page 54 Figure 4-1. E1343A, E1344A, E1345A, E1347A Multiplexer Block Diagram 52 Service Chapter 4...
  • Page 55: E1355A/56A Strain Gage Multiplexer Descriptions

    The E1355A and E1356A multiplexers, together with an E1326B or E1411B multimeter, provide static and dynamic strain measurement Gage Multiplexer capabilities for an Agilent 75000 Series B or 75000 Descriptions Series C VXIbus system. The E1355A and E1356A multiplexer are B-Size, 8-Channel, 120Ω and 350Ω...
  • Page 56 Figure 4-2. E1355A/56A Multiplexers Block Diagram 54 Service Chapter 4...
  • Page 57: Chapter 4 Service

    Table 4-1. E1355A/E1356A Relay Functions Relay Function Notes K100 Measure strain (channel 00) All strain gage measurements are made via the K101 Measure strain (channel 01) K90 relay connected to a multimeter K102 Measure strain (channel 02) K103 Measure strain (channel 03) K108 Measure strain (channel 04) All strain gage measurements are made via the...
  • Page 58: Troubleshooting Techniques

    Problem using these steps, perform component-level troubleshooting using the parts locator diagram in Chapter 3 (Figure 3-1) and the schematic diagrams located at the back of this manual. Table 4-2. E1343A/44A/45A/47A/55A/56A Typical Problems Problem Type Symptom Possible Solutions Operator Errors...
  • Page 59: Making Visual Checks

    NOTE and IRQ settings. If there are no apparent problems following the visual checks, run the Performance Verification Tests in Chapter 2 to see if a relay or other component is defective. Table 4-3. E1343A/44A/45A/47A/55A/56A Visual Tests/Checks Test/Check Reference Check...
  • Page 60: Testing The Multiplexer

    Testing the You can use the tests and checks in Chapter 2, "Verification Tests," and the information in Table 4-4 to isolate the problem to a relay, to a component, Multiplexer or both. For example, if Test 2-1: Closed Channel Resistance Test failed for channel 0, replace relay K100, etc.
  • Page 61: Repair And Maintenance Guidelines

    Repair and Maintenance Guidelines This section provides guidelines for handling the relay multiplexers including: • ESD precautions • Soldering printed circuit boards • Post-repair safety checks ESD Precautions Electrostatic discharge (ESD) may damage static sensitive devices in the multiplexers. This damage can range from slight parameter degradation to catastrophic failure.
  • Page 62: Component Locators And Schematic Diagrams

    E1343/44/45/47/55/56A multiplexer. Table 4-7 lists the terminal module diagrams. The terminal module diagram table applies to all E1343A/44A/45A/47A/56A/57A multiplexers, regardless of their serial number. Table 4-5. Relay Multiplexers Component Locator and Schematic Diagram Drawings...
  • Page 63 Table 4-7. Terminal Module Component Locator and Schematic Diagram Drawings (for all E1343A/44A/45A/47A/55A/56A Relay Multiplexers, regardless of serial number) Part Number Drawing Number Drawing Title Component E1345-66510 L-E1345-66510 E1343A/E1345A 16-Ch. Relay Multiplexer Terminal Card Locators E1347-66510 L-E1347-66510 E1344A/E1347A 16-Ch. Thermocouple Relay Multiplexer...
  • Page 64 Notes 62 Service Chapter 4...
  • Page 65: Appendix A. Verification Tests - C Programs

    Appendix A Verification Tests - C Programs Functional Verification Test These programs are designed to do the Functional Verification Tests found in Chapter 2, "Verification Tests." Example: Self-Test The Functional Verification Test for the multiplexer modules consists of sending the command and checking the response.
  • Page 66: Example: Closed Channel Resistance Test

    Performance These programs are designed to do the Performance Verification Tests found in Chapter 2, "Verification Tests." Verification Tests Example: Closed The following program performs a Closed Channel Resistance Test on Channels 00 - 15 and 90 - 92 HI, LO, and GU. If the conntact resistance for Channel a channel is >...
  • Page 67 iprintf (dm, "TRIG SGL\n"); iscanf (dm, "%lf", &R[i]); iscanf (dm, "%t", cr); printf ("\nResistance of R%u = %lf", i+38, R[i]); printf ("\n\n\nInstall Component Assembly and Test Fixture"); printf ("\n\n 1. Turn Mainframe AND 3458a DMM power OFF."); printf ("\n 2. Connect HP-IB Cable between mainframe and DMM."); printf ("\n 3.
  • Page 68 j = 100; for (i = 0;i <= 2; i++) iprintf (id, "CLOS (@%u)\n", j); iprintf (dm, "TRIG SGL\n"); iscanf (dm, "%lf", &value1[i][1]); iscanf (dm, "%t", cr); iprintf (id, "OPEN (@%u)\n", i*8); result1[i][1] = value1[i][1] - R[42]; if (result1[i][1] < 0) result1[i][1] = 0; if (result1[i][1] >...
  • Page 69 getchar (); iprintf (id, "CLOS (@%u)\n", j); iprintf (dm, "TRIG SGL\n"); iscanf (dm, "%lf", &value1[0][3]); iscanf (dm, "%t", cr); result1[0][3] = value1[0][3] - R[38] - R[43]; iprintf (id, "open (@%u)\n", j); if (result1[0][3] < 0) result1[0][3] = 0; if (result1[0][3] > 2.0) printf ("\n*** Resistance for Channel 93 HI Relay is 2.0 Ohms");...
  • Page 70: Example: Dc Isolation Test

    printf ("\n\nChannels 90-92 LO and G Contact Resistance\n"); printf ("\n CH 90 LO %6.4lf Ohms CH 91 LO %6.4lf Ohms CH 92 LO %6.4lf Ohms", result1[0][1],result1[1][1],result1[2][1]); printf ("\n CH 90 G %6.4lf Ohms CH 91 G %6.4lf Ohms CH 92 G %6.4lf Ohms", result1[0][2],result1[1][2],result1[2][2]);...
  • Page 71 iprintf (dm, "TRIG SGL\n"); iscanf (dm, "%t", reading); printf ("\nDC Isolation -- HI to CHASSIS "); printf (" R = %s Ohms", reading); /*......HI to LO........*/ printf ("\n\nConnect DMM HI and LO to E1346A COMMON HI and COMMON LO"); getchar (); iprintf (dm, "TRIG SGL\n");...
  • Page 72 Notes 70 Example C Programs Appendix A...
  • Page 73: Appendix B. Backdating Information

    Table B-4 shows reference designators for parts in Tables B-2 and B-3. To order a part listed in Table B-2 or Table B-3, specify the Agilent part number and the quantity required. Send the order to your nearest Agilent Technologies Sales and Service Office...
  • Page 74 Terminal Case Assembly, use E1300-84401. Table B-1. Relay Multiplexer Assembly/Terminal Module Part Numbers Multiplexer Component Terminal Terminal Card Terminal Assembly Module Case Assy E1343A 16-Channel High Voltage Relay E1343-66201 E1343-80001 E1345-66510 E1300-84401 E1343-66201 E1344-80001 E1347-66510 E1300-84401 E1344A 16-Channel High Voltage Relay...
  • Page 75 Reference Part Part Description Designator Number COMPONENT ASSY (CONT’D...HP E1345-66201) 1252-1596 CONN-POST TYPE 2.54-PIN-SPCG 96-CONTACT 1252-3712 CONN-POST TYPE .100-PIN-SPCG 12-CONTACT 1251-6001 CONN-POST TYPE .100-PIN-SPCG 6-CONTACT K0-K15 0490-1707 RELAY-REED 3A 500MA 110VAC 5VDC-COIL 5VA K90-K93 MP1-MP2 1400-1546 BRACKET PC BOARD HOLDER; BLACK; EXTR 1252-1596 CONN-POST TYPE 2.54-PIN-SPCG 96-CONTACT P3-P4...
  • Page 76 Reference Part Part Description Designator Number COMPONENT ASSY (CONT’D...HP E1345-66201) A1U1-U3 1858-0069 TRANSISTOR ARRAY 18-PIN PLASTIC DIP A1U5 1820-4057 IC BUFFER TTL/F NAND QUAD 2-INP A1U6 1820-6731 IC GATE-ARRAY CMOS A1U7-U8 1820-3079 IC DCDR CMOS/74HC BIN 3-TO-8-LINE A1U9 1820-3081 IC FF CMOS/74HC D-TYPE POS-EDGE-TRIG A1U10-U11 1820-3975 IC-DRIVER CMOS/74HC LINE OCTAL...
  • Page 77 Table B-3. E1343A, E1344A Replaceable Parts (See applicable Serial Number ranges listed on the first page of this chapter)) Reference Part Number Qty. Part Description Designator ASSEMBLIES/TERMINAL MODULES/CABLES ASSEMBLIES/TERMINAL MODULES E1343-66201 COMPONENT ASSEMBLY E1343-80001 E1343A TERMINAL MODULE E1344-80001 E1344A TERMINAL MODULE...
  • Page 78 Reference Part Number Qty. Part Description Designator COMPONENT ASSY (CONT’D...E1343-66201) PRINTED CIRCUIT ASSY, 16 CHAN MULTI A1C1 0180-1746 CAPACITOR-FXD 15uF +-10% 20 V TA 0160-4822 CAPACITOR-FXD 1000pF +-5% 100 V CER C0G A1C2-C3 A1C5 0160-4801 CAPACITOR-FXD 100pF +-5% 100 V CER C0G A1C6 0160-4822 CAPACITOR-FXD 1000pF +-5% 100 V CER C0G...
  • Page 79 IC TRANSCEIVER TTL/ALS BUS OCTL A1U38 1820-4086 IC FF CMOS/74HCT D-TYPE POS-EDGE-TRIG TERMINAL MODULES E1343-80001 E1343A TERMINAL MODULE (See Figure B-2) E1345-66510 TERM CARD - 16 CH RLY MUX E1300-84401 CASE - TERM MODULE ASSY E1344-80001 E1344A TERMINAL MODULE (See Figure B-2)
  • Page 80: Parts Locators

    Parts Locators Figures B-1 through B-3 show locations of replaceable parts for the E1343A, E1344A, E1345A, E1347A, E1355A, and E1356A Relay Multiplexers with serial numbers that fall within a specific range. (See applicable serial number ranges on the first page of this chapter.) See Table B-4 for Reference Designators.
  • Page 81 Figure B-2. E1343A/44A/45A/47A Terminal Module Mechanical Parts Appendix B Backdating Information 79...
  • Page 82 Figure B-3. E1355A/56A Terminal Module Mechanical Parts 80 Backdating Information Appendix B...
  • Page 84 Copyright © Agilent Technologies, Inc. 2005 *E1345-90013* E1345-90013...

This manual is also suitable for:

E1344aE1356aE1345aE1347aE1355a

Table of Contents