Electrical Connection - GE PDW9880J Brochure & Specs

Zoneline deluxe 2900 series, dry air 25 series, deluxe 3900 series, premium 5800 series packaged terminal air conditioners

Advertisement

Premium models
5800 series
Highly featured microcomputer controls
Cross-flow blower
Quiet blower reduces
annoying "Air rush" noise.
Reversible louver
(not shown)
May be reversed to
provide an air discharge
angle of 0 or 50 degrees
off vertical with the
removal of six screws.
3 position vent control
(not shown)
Opens vent. Provides up
to 70 cfm of outdoor air.
The closed position saves
energy by recirculating
conditioned room air.
Solid state
thermostat control
Provides better room
temperature control
vs. electromechanical
temperature control
device.
Freeze Sentinel
Provides automatic
protection against
freezing by switching
the unit to heat should
Auto frost
the temperature of an
control monitor
unoccupied room drop
A special sensor monitors
to 1°F.
the roomside coil to
prevent efficiency-robbing
Heat Sentinel
accumulation of frost
Provides automatic
during cooling cycle.
protection against
overheating by switching
Electronic
on the unit to cool should
temperature limiting
the temperature of
Preset cooling and heating
an unoccupied room
limits with 7 independent
reach 85°F.
cooling and 7 heating
limits—saves energy by
Room occupancy
preventing over-cooling or
sensor compatible
over-heating of rooms.
Ready for connection
to room occupancy
"Smartfan"
sensor system.
fan cycle selection
Select fan cycle or fan
Weather-protected
continuous independently
electrical components
for heating and cooling.
On inside of barrier.
Wall sleeve dimensions
Heavy-gauge galvanized
steel with a baked enamel
finish for outstanding
protection and appearance.
RAB71A wall sleeve
Heavy-gauge galvanized steel, with insulation.
A-", B-1 /", C-1"
RAB77A4 wall sleeve
(shown above)
Molded SMC fiberglass-reinforced polyester compound.
A- 1/8", B-1 7/8", C-1 1/"
Wall opening dimensions
Add 1/" to A and C dimensions for all cutout sizes.
RAB71 1 1/" min. H. x  1/" min. W.
RAB71 available in 1", ", 8" and 1" depths.
RAB77A 1 1/" min. H. x  /8" min. W.
Universal power cord
Flexibility of heat
applications. Each
premium line Zoneline
contains a bank of
 heaters.
Microcomputer controls
Electronic components
for fast response and
accuracy.

Electrical connection

A
0/08 volt units may be plugged into
a receptacle. 5 volt units are provided
with a junction box and require direct
C
connection. (NEC Requires 5V Direct
Connection.) See Architects and Engineers
Design Data Manual for electrical
connection information including use of
B
sub-base for direct-connected units. Installation
must comply with local electrical codes and regulations.
Ducted applications
900 and 900 series can be used with ductwork to heat or cool more
than one room. RAK05 Duct Adapter is applied to top of case over air
discharge. RAK01 Duct Extension is applied to right or left of adapter.
Locally fabricated ductwork may be added to extend to maximum
recommended distance of 15 feet.
For additional information on ducted applications, including special
adapters for replacement units, refer to Architects and Engineers Design
Data Manual.
Two fan motors
(not visible)
Separate motors for
indoor and outdoor fans
to assure quiet operation.
Touch pad controls
With electronic control
temperature display.
Gives the user finer
control over the
temperature.
Reverse cycle defrost
(not shown)
Solid state sensor
monitors frost build-up
on outdoor coil. When
frost is detected, the
refrigerant flow is reversed
to melt frost build-up.
When completed, the
refrigerant is reversed
to the normal energy
saving heat pump
operation for additional
heat pump operating hours.
Rotary compressor
Central desk
With fewer moving
control compatible
parts than reciprocating
models for quiet,
Ability to turn the unit
reliable operation.
"on" or "off" from a
remote location.
Easy-access filter
Remote control
(not shown)
compatible
Two upfront filters
Ability to be controlled
are part of roomside
by a wall-mounted
cabinet for easy access
and maintenance.
thermostat with high
or low fan speed.
ge.com