Agilent N5416A USB 2.0 Compliance Test Software
Release Notes
Agilent N5416A Software Version 03.81
Released Date: 28 October 2013
Minimum Infiniium Oscilloscope Baseline Version: 4.20 (90000 series),
4.6(9000 series)
Minimum Infiniium Oscilloscope Baseline Version: 4.60.0005 (90000 series),
4.6(9000 series)
File Name: SetupInfUSBXP0381.exe
Modifications:
1.
To upgrade framework to 0391 and support layer to 2.01
2.
Fixed the problem where Upstream Low Speed test able to run at first
trial, however at second trial, the test aborts with error message "Did not find
correct waveform".
3.
For Inrush Current set the sensitivity to HIGH and the Acquisition to High
Resolution Auto mode.
4.
Fixed test abort intermittently when ran Suspend / Resume Timing, to
turn off Bandwith limit to fix this issue. (This issue only affect window 7, it had
been fixed by using baseline 4.6)
5.
Fixed test abort occasionally on Signal Quality Test with error message
"HSSQDevice0.tsv" was not found, especially when ran repetitive. This is due to
waveform file was not properly saved.
6.
Fixed connection error where connection break when ran with 81130A.
This is due to GPIB command error. (*IDN?;*OPT?)
Agilent N5416A Software Version 03.80
Released Date: 14 June 2013
Minimum Infiniium Oscilloscope Baseline Version: 4.20 (90000 series), 4.20
(9000 series)
File Name: SetupInfUSBXP0380.exe
Modifications:
 Embedded Host Test update
 Remove the lost from Agilent fixture using InfiniiSim.
Agilent N5416A Software Version 03.74
Released Date: 27 May 2013
Page 1 of 9

Advertisement

loading

Summary of Contents for Agilent Technologies N5416A

  • Page 1 Minimum Infiniium Oscilloscope Baseline Version: 4.20 (90000 series), 4.20 (9000 series) File Name: SetupInfUSBXP0380.exe Modifications:  Embedded Host Test update  Remove the lost from Agilent fixture using InfiniiSim. Agilent N5416A Software Version 03.74 Released Date: 27 May 2013 Page 1 of 9...
  • Page 2  Updated USB-IF’s USBET dll to version 1.20  Upgraded framework to version 3.82  This is last version for 80000 series oscilloscope. Agilent N5416A Software Version 03.73 Released Date: 6 April 2012 Minimum Infiniium Oscilloscope Baseline Version: 5.71 (80000 series), 2.40 (90000 series), 2.40 (9000 series)
  • Page 3 File Name: SetupInfUSBXP0370.exe Modifications:  Upgraded framework to version 3.40 to support DSOX90000 series oscilloscopes. Agilent N5416A Software Version 03.60 Released Date: 10 April 2010 Minimum Infiniium Oscilloscope Baseline Version: 5.71 (80000 series), 1.41 (90000 series), 2.00 (9000 series) File Name: SetupInfUSBXP0360.exe Modifications: ...
  • Page 4  Changed Inrush Current Test to trigger only once then fail the test if failed to trigger.  Corrected connection instructions for bus-powered hub Drop Test using the new fixture. Agilent N5416A Software Version 03.40 Released Date: 20 May 2008 Minimum Infiniium Oscilloscope Baseline Version: 5.20 (80000 series), 1.00 (90000 series) File Name: SetupInfUSBXP0340.exe...
  • Page 5 Agilent N5416A Software Version 03.30 Released Date: 10 Jan 2008 Minimum Infiniium Oscilloscope Baseline Version: 5.20 (80000 series), 1.00 (90000 series) File Name: SetupInfUSBXP0330.exe Additions:  Supports the Remote Interface Control.  Supports the Infiniium 90000 Series High Performance Oscilloscope.
  • Page 6 Agilent N5416A Software Version 03.20 Released Date: September 2007 Minimum Infiniium Oscilloscope Baseline Version: 05.20.00 File Name: SetupInfUSBXP0320.exe Additions  Added manual method in Signal Eye Quality tests for Hi speed, Full speed and low speed tests.  Added sensitivity option for the EL_28 Measure Device Chirp-K Latency Test.
  • Page 7 Agilent N5416A Software Version 03.10 Released Date: March 2007 Minimum Infiniium Oscilloscope Baseline Version: 05.20.00 File Name: SetupInfUSBXP0310.exe Additions  Supports Multitrial testing.  Added compliance features to allow customers to choose the hysteresis measurement level for non-Monotonic Edge Test.
  • Page 8 Agilent N5416A Software Version 03.02 Released Date: 20 Dec 2006 Minimum Infiniium Oscilloscope Baseline Version: 05.20.00 File Name: SetupInfUSBXP0302.exe Modifications:  Matlab migration from version 7.1 to version 7.5.  Code change for triggering the last packet of signal in Host/Hub Disconnect test.
  • Page 9 Agilent N5416A Software Version 03.01 Released Date: 17 Oct 2006 Minimum Infiniium Oscilloscope Baseline Version: 03.90.00 File Name: SetupInfUSBXP0301.exe Additions  OTG test supports Cypress boards (and any other manual OTG test boards) in debug mode.  Supports MATLAB script both versions 2.10 and 2.12.