Fluke 190-502/AM Technical Data Manual page 2

Datasheet
Hide thumbs Also See for 190-502/AM:

Advertisement

Oscilloscope modes
Vertical deflection
Number of channels
Bandwidth
Rise time
Number of scope inputs
Channel architecture
Input coupling
Input sensitivity
Bandwidth limiter
Normal/invert/variable
Input voltage
Vertical resolution
Accuracy
Input impedance
Horizontal
Maximum real-time sample
rate (sampled simultaneously)
Record length
Time base range
Maximum record length
Timing accuracy
Glitch capture
Display and acquisition
Display
Display modes
Visible screen width
Digital persistence modes
Waveform mathematics
Acquisition modes
Trigger and delay
Source
Modes
Connect-and-View
Video triggering (on ch. A)
High-res, non-interlaced video
Pulse width triggering
(on channel A)
Time delay
Dual slope triggering
N-cycle triggering
2 Fluke Corporation
2 Fluke Corporation
ScopeMeter 190 Series II
ScopeMeter 190 Series II
Shop for Fluke products online at:
190-062
190-102
2
2
60 MHz
100 MHz
5.8 ns
3.5 ns
2 input channels plus external trigger
All inputs fully insulated from each other and from ground
Inputs may be activated in any combination
AC or DC, with ground level indicator
2 mV/div to 100 V/div, plus variable attenuation
User selectable: 20 kHz, 20 MHz or full bandwidth
On each input channel, switched separately
CAT III 1000 V/CAT IV 600 V rated, see General Specifications for further details
8 bit
± (2.1 % of reading + 0.04 x range/div) @ 5 mV/div to 100 V/div
1 MΩ ± 1 % // 14 pF ± 2 pF
625 MS/s for
1.25 GS/s for
each channel
each channel
Up to 10,000 samples per channel
10 ns/div
5 ns/div
to 4 s/div
to 4 s/div
Time base in a 1-2-4-sequence
Slower time/division settings using ScopeRecord
10,000 samples per channel in scope mode;
30,000 points per channel in ScopeRecord
± (0.01 % of reading + 1 pixel)
8 ns peak detect on each channel
(using real time sampling and data compression, at any timebase setting)
153 mm (6 in) full-color LCD with LED backlight
Any combination of channels; average on/off; replay
12 divisions horizontally in scope mode
off/short/medium/long/infinite and envelope mode
One mathematical operation on any 2 input channels: add/subtract/multiply; X-Y-mode
Frequency Spectrum using FFT analysis
Normal, Averaged, Auto, Single Shot, ScopeRecord™ roll, glitch capture,
waveform compare with automatic "Pass/Fail testing"; Replay
Input A, B or External (via meter input)
Automatic Connect-and-View
, free run, single shot, edge, delay, dual slope,
video, video line, selectable pulsewidth (channel A only), N-cycle
Advanced automatic triggering that recognizes signal patterns, automatically sets up and continuously adjusts
triggering, time base and amplitude. Automatically displays stable waveforms of complex and dynamic signals
like motor drive and control signals. Can be switched off if preferred.
NTSC, PAL, PAL+, SECAM; Includes field 1, field 2 and line select
Non-interlaced video with line-select, for line frequencies in the range 14 kHz up to 65 kHz
Pulse width qualified by time
Allows for triggering <t, >t, =t, ≠ t, where t is selectable in minimum steps of 0.01 div or 50 ns
1 full screen of pre-trigger view or up to 100 screens (=1,200 divisions) of post-trigger delay
Triggers on both rising and falling edges alike
Triggers on N-th occurrence of a trigger event; N to be set in the range 2 to 99
MyFlukeStore
www.
190-202
190-502
2
2
200 MHz
500 MHz
1.7 ns
0.7 ns
2.5 GS/s (2ch)
5 GS/s (single
channel) or 2.5
GS/s (on 2ch)
2 ns/div
1 ns/div.
to 4 s/div
to 4 s/div.
Roll mode (see 'Recorder mode')
Roll mode (see 'Recorder mode')
.com
190-104
190-204
4
4
100 MHz
200 MHz
3.5 ns
1.7 ns
4 input channels
1.25 GS/s for
2.5 GS/s (2ch)
each channel
1.25 GS/s (4ch)
5 ns/div
2 ns/div
to 4 s/div
to 4 s/div
Input A, B, C or D