Temperature Ranges; Specifications - Fluke 1623 Datasheet

Fluke 1623 and 1625 geo earth ground testers datasheet
Hide thumbs Also See for 1623:
Table of Contents

Advertisement

The most complete testers
The Fluke 1623 and 1625 are distinctive earth
ground testers that can perform all four types of
earth ground measurement:
3- and 4-Pole Fall of Potential (using stakes)
4-Pole Soil Resistivity testing (using stakes)
Selective testing (using 1 clamp and stakes)
Stakeless testing (using 2 clamps only)

1623 Specifications

General
Display:1999 digit LCD
User interface
Robust and waterproof

Temperature ranges

Working temperature
Operating temperature
Storage temperature
Reference temperature
The chart of four temperature ranges for the instrument exist to satisfy European Standards requirements; the instrument can be used over the full working
temperature range by using the temperature coefficient to calculate accuracy at the ambient temperature of use.
Temperature coefficient
Intrinsic error
Operating error
Climatic class
Protective type
Safety
EMC (Emission Immunity)
Quality system
External voltage
V ext rejection
Measuring time
Max. overload
Auxiliary power
Battery life span
Dimensions (WxHxD)
Weight
2 Fluke Corporation
1623 and 1625 GEO Earth Ground Testers
The testers are also easy to use. For each test,
the testers inform you which stakes or clamps need
to be connected and the large rotary switch can be
used even with a gloved hand.
The complete model kit comes with the 1623
or 1625 tester, test leads, 4 earth ground stakes,
3 cable reels with wire, 2 clamps, batteries, and
manual—all inside a rugged Fluke carrying case.
Display with special symbols, digit height 25 mm, fluorescent backlight
Instant measurement through TURN and START one button concept. The only operating elements are
rotary switch and START button
Instrument is designed for tough environmental conditions (rubber protective cover, IP56)
-10 °C to 50 °C (14 °F to 22 °F)
0 °C to 35 °C (32 °F to 95 °F)
-20 °C to 60 °C (-4 °F to 140 °F)
23 °C to ± 2 °C (73 °F to ± 4 °F)
± 0.1 % of reading/K
Refers to the reference temperature range and is guaranteed for 1 year
Refers to the operating temperature range and is guaranteed for 1 year
C1 (IEC 654-1), -5 °C to +45 °C (23° to +115° F), 5 % to 95 % RH
IP56 for case, IP40 for battery door according to EN60529
Protection by double and/or reinforced insulation. max. 50 V to earth
IEC 61326-1:1997 Class A
Developed, designed and manufactured according to DIN ISO 9001
V ext, max = 24 V (dc, ac < 400 Hz), measurement inhibited for higher values
> 120 dB (16
2
, 50, 60, 400 Hz)
3
Typical 6 sec.
250 V rms (pertains to misuse)
6 x 1.5 V mignon cells alkali-manganese (type AA LR6)
Typical > 3,000 measurements
250 mm x 133 mm x 187 mm (9.75 in x 5.25 in x 7.35 in)
1.1 kg (2.43 lb) including batteries

Advertisement

Table of Contents
loading

This manual is also suitable for:

1625

Table of Contents