Download Print this page

Jenn-Air JGCP430W Product Dimensions

Commercial style gas cooktop

Advertisement

Quick Links

Commercial Style Gas Cooktop
PRODUCT MODEL NUMBERS
JGCP430W
JGCP536W
JGCP436W
JGCP548W
Type of Gas
Natural Gas:
This cooktop is design-certified by CSA International for
use with Natural gas or, after proper conversion, for use
with LP gas.
This cooktop is factory-set for use with Natural gas. To
convert to LP gas, see the Gas Conversion instructions
provided in the package containing literature. The model/
serial rating plate located on the left underside of the
cooktop burner base has information on the types of gas
that can be used. If the types of gas listed do not include
the type of gas available, check with the local gas supplier.
LP Gas conversion:
Conversion must be done by a qualified service technician.
No attempt shall be made to convert the cooktop from the
gas specified on the model/serial rating plate for use with a
different gas without consulting the serving gas supplier. To
convert to LP gas, use the LP gas converision kit provided
with the cooktop and see the "Gas Conversions" section.
Electrical:
A 120 volt, 60 Hz, AC only, 15-amp, fused electrical circuit
is required. A time-delay fuse or circuit breaker is also
recommended. It is recommended that a separate circuit
serving only this cooktop be provided.
Electronic ignition systems operate within wide voltage
limits, but proper grounding and polarity are necessary.
Check that the outlet provides 120-volt power and is
correctly grounded.
LOCATION REQUIREMENTS
IMPORTANT: Observe all governing codes and ordinances.
Do not obstruct flow of combustion and ventilation air.
It is the installer's responsibility to comply with
installation clearances specified on the model/serial rating
plate. The model/serial rating plate is located on the
underside of the cooktop burner base.
It is recommended that a 600 CFM or larger vent hood be
installed above the cooktop.
It is not recommended that a microwave hood
combination be mounted above the cooktop.
The cooktop should be installed in a location away from
strong draft areas, such as windows, doors and strong
heating vents or fans.
All openings in the wall or floor where cooktop is to be
installed must be sealed.
Cabinet opening dimensions that are shown must be
used. Given dimensions are minimum clearances.
Grounded electrical supply is required. See "Electrical
Requirements" section.
Proper gas supply connection must be available. See "Gas
Supply Requirements" section.
The cooktop is designed to hang from the countertop by
its side or rear flanges.
The gas and electric supply should be located as shown in
"Gas and Electric Connection Locations" section so that
they are accessible without requiring removal of the
cooktop.
Provide cutout in left rear corner of cutout enclosure as
shown to provide clearance for gas inlet, power supply
cord, and to allow the rating label to be visible.
IMPORTANT: To avoid damage to your cabinets, check with
your builder or cabinet supplier to make sure that the
materials used will not discolor, delaminate or sustain other
damage.
Mobile Home - Additional Installation Requirements
The installation of this cooktop must conform to the
Manufactured Home Construction and Safety Standard,
Title 24 CFR, Part 3280 (formerly the Federal Standard for
Mobile Home Construction and Safety, Title 24, HUD Part
280). When such standard is not applicable, use the
Standard for Manufactured Home Installations, ANSI
A225.1/NFPA 501A or local codes.
In Canada, the installation of this cooktop must conform
with the current standards CAN/CSA-A240-latest edition, or
with local codes.
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
PRODUCT DIMENSIONS
A
E
D
A. 27 " (68.9 cm)
B. 30" (76.2 cm) cooktop:
29
" (75.1 cm) actual width
36" (91.4 cm) cooktop:
35
" (90.4 cm) actual width
48" (121.9 cm) cooktop:
47
" (120.8 cm) actual width
Side View of Cooktop
G
F
A. 27¾" (70.5 cm)
B. 1¼" (3.2 cm)
C. 7
" (18.8 cm)
D. Gas inlet is located 1 " (4.8 cm) from the back of
the cooktop burner base and 4 " (12.4 cm) in
from left-hand side of the cooktop burner base.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
B
C. Island trim or optional backguard
D. 36" (91.4 cm) long 3 prong grounding-
type power supply cord
E. Model/serial rating plate (located on the
underside of the cooktop burner base)
A
B
E
D
E. 22" (55.9 cm)
F. 3
" (8.4 cm)
G.
" (1.4 cm)
C
C
Page 1 of 2
Ref. W10145395
03/05/2010

Advertisement

loading

Summary of Contents for Jenn-Air JGCP430W

  • Page 1 Commercial Style Gas Cooktop PRODUCT MODEL NUMBERS PRODUCT DIMENSIONS JGCP430W JGCP536W JGCP436W JGCP548W Type of Gas Natural Gas: This cooktop is design-certified by CSA International for use with Natural gas or, after proper conversion, for use with LP gas. This cooktop is factory-set for use with Natural gas. To convert to LP gas, see the Gas Conversion instructions provided in the package containing literature.
  • Page 2 Commercial Style Gas Cooktop CABINET REQUIREMENTS A. Grounded 3-prong outlet should be located on Gas and Electric left-hand side of the cutout 16" (40.6 cm) max. Connection Locations from enclosure sidewall B. 10" (25.4 cm) min. clearance from countertop to top of the outlet C.

This manual is also suitable for:

Jgcp436wJgcp536wJgcp548w