Mitsubishi Electric MSZ-D30NA Service Manual page 22

Split-type, heat pump air conditioner
Hide thumbs Also See for MSZ-D30NA:
Table of Contents

Advertisement

9-3. INSTRUCTION OF TROUBLESHOOTING
Start
Indoor unit oper-
ates.
Outdoor unit
doesn't operate.
Outdoor unit
Outdoor
operates only
unit doesn't
in Test Run
operate even
operation.
in Test Run
operation.
Check room
Refer to "How
temperature
to check
thermistor.
inverter/
Refer to 8-7.
compressor".
"Test point
diagram and
voltage".
Left lamp
Left lamp
Flash on and
2-time fl ash
off at 0.5-sec-
Cause:
ond intervals
Indoor unit
Cause:
• Trouble of
Indoor/ Out-
room tem-
door unit
perature /
• Miswiring or
indoor coil
trouble of
thermistor
serial signal
Refer to 9-6.
Check room
"How to
temperature
check miswir-
thermistor
ing and serial
and indoor
signal error".
coil thermis-
tor.Refer to
9-7."Test
point diagram
and voltage".
Indoor unit operates.
Outdoor unit doesn't
operate normally.
Indoor unit
Unit doesn't
operates, when
operate normal
EMERGENCY
operation in
OPERATION
COOL or HEAT
switch is pressed.
mode.
Refer to
Refer to 9-6.
"Check of R.V.
"Check of remote
coil".
controller and
receiver P.C.
board".
Left lamp
Left lamp
3-time fl ash
4-time fl ash
Cause:
Cause:
Indoor unit
Indoor unit
• Trouble of
• Trouble
indoor fan
of indoor
motor
unit control
system
Refer to 9-6.
Replace the
"Check of
indoor elec-
indoor fan
tronic control
motor".
P.C. board.
Indoor unit
OPERATION INDICATOR
doesn't receive
lamp on the indoor unit is
the signal from
fl ashing on and off.
remote controller.
Indoor unit
doesn't operate,
when EMERGEN-
CY OPERATION
switch is pressed.
1.Check indoor / out-
door connecting wire.
(Check if the power is
supplied to the indoor
unit.)
2.Refer to 9-6.
"Check
of indoor electronic
control P.C. board and
indoor fan motor".
Left lamp
Left lamp
6-time fl ash
5-time fl ash
Cause:
Cause:
Outdoor unit
Outdoor unit
• Trouble of
• Outdoor
power
thermistor in
outdoor unit
system
abnormality
Refer to "How
Refer to
to check
"Check of
inverter/ com-
outdoor
pressor".
thermistors".
22
22
If blinking of OPERATION INDI-
CATOR lamp cannot be checked,
it can be checked with failure
mode recall function.
"Test Run operation" means the
operation within 30 minutes after
EMERGENCY OPERATION
switch is pressed.
Refer to outdoor unit service manual.
Left lamp
Left lamp
7-time fl ash
14-time fl ash
Cause:
Cause:
Outdoor unit
Outdoor unit
• Trouble of
• Other ab-
outdoor con-
normality
trol system
Replace the
Check "Flow
inverter P.C.
chart of the
board or the
detailed
outdoor elec-
outdoor unit
tronic control
failure mode
P.C. board.
recall func-
tion."