Installation

Preparation
Remove all packaging material including polystyrene base.
While opening the package, water drops may be seen on
plastic bag and porthole. This normal phenomenon results
from water tests in the factory.
Dismantle the transportation bolts
1
.
The transportation bolts are designed for clamping anti-
vibration components inside the appliance during transpor-
tation.
1. Remove the back cover.
2.
2
.
2. Remove bolts on the rear side and take out
from inner side of the machine.
General information and tips:
Keep the transportation bolts in a safe place for later use.
If the machine is to be moved to another location, replace
transportation bolts contrariwise to prevent damage.
3. Replace back cover by inserting it in the two gaps its con-
4
.
3.
3
3
.
.
vexity is facing outside
4. Fill left holes with blanking plugs.
4
.
Adjusting the feet
Adjust all feets to achieve a complete level position.This will
minimize vibrations and thus noise during use. It will also
reduce wear and tear. We recommend to use a spirit level
for adjustment. Floor should be as stable and flat as possible.
22
23
Inlet hose - Aqua control System
The Aqua Stop inlet hose is an important element for safety
and over all control. Its valves are controlling water supply
and will interrupt it if the hose is leaking
1. Connect the nut on the inlet hose to the connector
on the water valve.
2. Apply inlet hose to a water tap.
Warning!
plastic spacers
Appliance is only qualified for cold water supply!
Use the hose-set supplied with the appliance.
Old hose-sets should not be reused.
Drain hose
Drainage could be installed in different ways. Nevertheless,
level of drain hose has to reach at one point 80-100 cm.
If possible keep always drain hose fixed to the clip at the
appliance back.
1. Drain hose to sink
Use the drain hose bracket to keep drain hose end retained
and out of any water level.
Fix the bracket sufficiently to avoid dropping down due to
operational movements.
2. Drain hose to sink siphon
Connection has to be securely sealed and fixed to corres-
pondig adapter above the siphoning part!
Installation
80 - 100 cm